Extend the server from the rack.
•
Remove the server from the rack.
4.
5.
Do one of the following:
•
•
If installed, remove the 4LFF midplane drive cage.
6.
7.
Disconnect the power switch module cable from the power switch/SID module connector.
The SID module cable will be connected to this same connector.
8.
Remove the power switch module. Retain the T-10 screw for later use.
CAUTION: When routing cables, make sure that the cables are not in a position where they can be pinched or
crimped.
9.
Route the SID cable through the opening in the front of the server, and then install the SID module. Secure the module
using the T-10 screw removed in step 8.
Hardware options installation
142