15.
Connect each power cord to the server.
16.
Connect each power cord to the power source.
18.
If removed,
The installation is complete.
Fan option
Fan population guidelines
The number of fans installed in the server determines fan redundancy.
Configuration
Fan
redundancy
Bay 1
Bay 2
Bay 3
Bay 4
Bay 5
Bay 6
One processor,
without NVMe drives
and rear 2-SFF
drives installed
No
Blank
Blank
Blank
Fan
Fan
Fan
One processor,
without NVMe drives
and rear 2-SFF
drives installed
Yes
Blank
Fan
Blank
Fan
Fan
Fan
One processor, with
NVMe drives or rear
2-SFF drives
installed
No
Blank
Fan
Fan
Fan
Fan
Fan
One processor, with
NVMe drives or rear
2-SFF drives
installed
Yes
Fan
Fan
Fan
Fan
Fan
Fan
Two processors
No
Blank
Fan
Fan
Fan
Fan
Fan
Two processors
Yes
Fan
Fan
Fan
Fan
Fan
Fan
Fan mode behavior
• In nonredundant fan mode, a fan failure or a missing fan causes:
◦ The system Health LED to flash amber.
◦ The operating system to orderly shutdown.
• In redundant fan mode:
◦ A fan rotor failure will switch the system to nonredundant fan mode.
This change is indicated by the Health LED flashing amber. The system continues to operate
normally in this mode.
◦ A second fan rotor failure or a missing fan causes the operating system to orderly shutdown.
86
Hardware options installation
Содержание ProLiant DL180
Страница 30: ...24 bay SFF hot plug drive model Fan bay numbering 30 Component identification...
Страница 58: ...SFF 4 Install the drive LFF SFF 58 Hardware options installation...
Страница 97: ...Secondary riser cage Slot 4 Slot 5 or 6 Hardware options installation 97...
Страница 112: ...Secondary riser cage Rear 2 bay SFF drive cage 10 Remove the nonredundant power supply 112 Hardware options installation...
Страница 127: ...Cable routing SFF drive model Box 1 to type a controller Box 1 to type p controller Cabling 127...
Страница 128: ...Box 2 to type a controller Box 2 to type p controller 128 Cabling...
Страница 129: ...Box 3 to system board Box 3 to type a controller Cabling 129...
Страница 130: ...Box 3 to type p controller 8 bay SFF power cable default 130 Cabling...
Страница 135: ...Mini SAS cable to SAS expander Cabling 135...
Страница 137: ...M 2 SSD enablement board installed in secondary riser Cabling 137...
Страница 141: ...Cable routing USB 3 0 Cable routing Power supply HPE 500W power supply cabling non hot plug Cabling 141...
Страница 142: ...Cable routing Serial port Cable routing iLO Service Port SFF LFF 142 Cabling...
Страница 144: ...Secondary riser cage Slot 4 Slot 5 or 6 144 Cabling...
Страница 145: ...Cable routing GPU Color Description Orange GPU power cable Blue Rear 2 bay SFF power cable Cabling 145...