Power requirements
The following table lists the power requirements for the HPE DL20 G9 server.
Specification
Value
System VA rating
137.82 VA
System BTU HR
452.87 BTU
Input System Current
1.2 A
Utilization Power
132.81 W
Idle Input Power
43.69 W
Max Load Input Power
132.81 W
Physical system protection requirements
To properly ventilate the system, you must provide a minimum clearance of:
• 63.5 cm (25 in) in front of the rack
• 76.2 cm (30 in) behind the rack
Note:
You must ensure that no environmental hazards, such as, excessive heat, excessive humidity,
improper ventilation, or electromagnetic interference from proximate equipment interfere with
the operation of the HPE DL20 G9 server.
Front view of the HP DL380 G9 server
Power requirements
July 2016
Avaya CMS HPE DL20 G9 and DL380 G9 HIMT
15