• A system “freeze”
• Server restarts or powers down unexpectedly
• Parity errors occur
Cause
• The DIMM is not installed or seated properly.
• The DIMM has failed.
Action
1.
Reseat the DIMM.
2.
Update the BIOS to the latest version.
3.
If the issue still exists, then replace the DIMM.
Correctable memory error threshold exceeded
Symptom
• Performance is degraded.
• The System Status LED is amber.
• ECC errors occur with no other symptoms.
Cause
• The DIMM is not installed or seated properly.
• The DIMM has failed.
Action
1.
Update the BIOS to the latest version.
2.
Replace the DIMM.
Processor issue
Troubleshooting the processor
Symptom
A POST error message or Redfish or IPMI Event LOG is received.
Troubleshooting
41
Содержание Cloudline CL2600 Gen10
Страница 62: ...VLAN Configuration Parameter Description Enter Configuration Menu VLAN VLAN Configuration 62 System utilities...
Страница 63: ...Driver Health Parameter Description Component UEFI driver Driver healthy status System utilities 63...
Страница 73: ...NVMe SSD Drives List System utilities 73...
Страница 103: ...b Remove the riser blank Full height Removal and replacement procedures 103...