Action
To determine if the server is supported, check BIOS or BMC Firmware release note and confirm the
server model.
5-6
Server does not boot
Symptom
The server does not boot.
Cause
The system BIOS or BMC Firmware flash process fails.
The system ROM corrupted.
The server boot failed due to updating the BIOS or BMC firmware failed, either through tool or webUI.
A logical drive is not configured on the RAID controller.
The controller boot order is not set properly.
RAID containing multiple logical drives might require the boot logical drive to be selected under Option
ROM.
Action
For BIOS flash process fail cause server does not boot, try to use BMC WebUI to update BIOS again.
BIOS Recovery process.
For BMC Firmware process fail cause server doesn’t boot, contact for repairing process.
A logical drive is not configured on the RAID controller. Configure logical drive on RAID controller and
set controller boot order properly.
Properly select boot logical drive under Option ROM when RAID containing multiple logical drives.