• Take the iLO label off the system board information label and place it over the iLO information pull tab
on the front panel.
• Install the spare system board.
• Remove the battery insulator strip from the system board battery.
• Install the processors and heat sink or processor heat sink module the system board (
• Install all components removed from the failed system board.
Removing and replacing the access panel
• Install the power supplies (
Removing and replacing a hot-swap power supply
on page 146).
• Power up the server.
CAUTION:
Replacement system boards are shipped with the RAID controller in HBA mode by default. When
the original components are re-installed on the replacement board and the system is booted to
UEFI, the
saupdate
utility must be used to re-enable the RAID configuration if the original server
was using the RAID functionality. See
saupdate
utility.
After you replace the system board, you must to set the SAS mode to RAID if that was your previous
configuration.
• During the server startup, wait for UEFI Front Page, press
S
to launch the UEFI Shell.
• Get the
saupdate.efi
utility tool.
• Enter
saupdate.efi set_mode 0:1:0:0 raid
to change the SAS mode to RAID.
• Enter
saupdate.efi get_mode 0:1:0:0
to verify the SAS mode is set to RAID.
After you replace the system board, you must port over the server serial number, product number and
UUID. Labels on the server indicates these numbers.
• Log in to iLO 3 MP, by using SSH, for example.
• Access the MP Main Menu.
• Enter
CM
at the
hpiLO->
prompt.
• Enter
sysset
at the
CM:hpiLO>
prompt, and it will show the system information.
• To change the serial number:
• a. Enter sysset -serial <serial number> at the CM:hpiLO-> prompt.
• b. Enter the associated password, and press Enter.
• To change product number (default is for the data center server):
• a. Enter sysset -prodnum <product number> at the CM:hpiLO-> prompt.
• b. Enter the associated password, and press Enter.
• To change the UUID:
• a. Enter sysset -uuid <uuid> at the MP:CM -> prompt.
Removal and replacement procedures
175