Removing and replacing a power supply blank
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all bays are
populated with either a component or a blank.
To remove the component:
Figure 30: Removing the blank
To replace the component, reverse the removal procedure.
Removing and replacing a hot-swap power supply
The server supports 1+1 redundant power supply for high line (1200W/200~240VAC) and low line (800W/
100~120VAC) in the data center and office-friendly server versions.
Table 44: Power redundancy configurations
Line voltage
Power supply
count
Processor count
DIMM count
Redundancy
High Line
(200-240)
1
1 or 2
2 to 24
No
High Line
(200-240)
2
1 or 2
2 to 24
Yes
Low Line (100-120) 1
1 or 2
2 to 12
No
Low Line (100-120) 2
1
2 to 12
Yes
Low Line (100-120) 2
2
Yes
A maximum of 8 DIMMs are supported in a configuration with low line AC voltage and 2 processors.