Grounding the work area
To prevent static damage in the work area:
●
Cover the work surface with approved static-dissipative material. Use a wrist strap connected to
the work surface, and properly grounded tools and equipment.
●
Use static-dissipative mats, foot straps, or air ionizers to give added protection.
●
Handle electrostatic-sensitive components, parts, and assemblies by the case or PCB laminate.
Handle them only in static-free work areas.
●
Disconnect power and input signals before inserting and removing connectors or test equipment.
●
Use fixtures made of static-safe materials when fixtures must directly contact dissipative surfaces.
●
Keep work area free of nonconductive materials, such as plastic assembly aids and Styrofoam.
●
Use field service tools (such as cutters, screwdrivers, and vacuums) that are conductive.
Recommended ESD prevention materials and equipment
The recommended materials and equipment are:
●
Antistatic tape
●
Antistatic smocks, aprons, and sleeve protectors
●
Conductive bins and other assembly or soldering aids
●
Conductive foam
●
Conductive tabletop workstations with a ground cord of one megohm ± 10% resistance
●
Static-dissipative table or floor mats with a hard-tie to ground
●
Field service kits
●
Static awareness labels
●
Wrist straps and footwear straps providing one megohm ± 10% resistance
●
Material-handling packages
●
Conductive plastic bags
●
Conductive plastic tubes
●
Conductive tote boxes
●
Opaque shielding bags
●
Transparent metallized shielding bags
●
Transparent shielding tubes
ENWW
Service considerations
67