Disable BGI
: No, Yes
●
Select Size
: Specify the size of the RAID array
5.
Click
Next
.
6.
A dialog warns you that if your Write Policy is set to:
●
Write Through
, the configuration may result in slower performance.
●
Always Write Back
, the configuration will result in optimal performance, but there is a
risk of data loss in the event of power failure.
●
Write Back with BBU
and you do not have BBU installed, write back is only enabled
when the battery has a sufficient charge, and that during a learning cycle the caching policy
will revert to write through until the learning cycle is complete.
7.
Click
Yes
to accept the warning, then click
Next
.
8.
Click
Accept
, then click
Yes
to save the configuration.
9.
Click
Yes
to initialize the virtual drive you just created.
Configuring RAID on an LSI 9260-8i MegaRAID controller
175