director product manager user guide
4–5
Using Logs
•
Date/Time—The date and time of the event on the director.
•
Event—Events are identified by a unique code. Event codes include:
The following acronyms may display in this column for the port card:
— GLSL—G_Port, long wave, single mode LC connector, 1 Gigabit
— GSML—G_Port, short wave, multimode, LC connector, 1 Gigabit
— GXXL—G_Port, mixed mode, LC connector, 1 Gigabit
— FPM—G_Port, small form factor optics (SFO) pluggable, FICON port
module, 1 Gigabit
— UPM—G_Port, small form factor optics (SFO) pluggable, universal port
module, 2 Gigabit
— GSF2—GPort, small form factor optics (SFO) pluggable, universal port
module, 2 Gigabit
— GLSR—G_Port, short wave, single mode, MT-RJ connector, 1 Gigabit
— GXXR—G_Port, mixed mode, MT-RJ connector, 1 Gigabit
— GSMR—G_Port, short wave, multimode, MT-RJ connector, 1 Gigabit.
The chassis (slot) position for a nonredundant FRU is 0. The chassis positions for
redundant FRUs are 0, 1, and 2. The chassis positions for port cards are
0 through 35, and slot 32 is unavailable.
•
Description—A short description of the event.
•
Severity—There are four classifications of severity that identify the importance of
the event.
Table 4–1: Event Codes
Code
Event
000–199
System events
200–299
Power supply events
300–399
Fan module events
400–499
CTP card events
500–599
Port card events
600–699
SBAR card events
800–899
Thermal events