12.
Select
File > Default Setup > Restore Factory Settings as Default
. This action resets
settings back to their factory defaults.
13.
Select
File > Apply Defaults and Exit
.
14.
Shut down the computer, remove the power cord, remove the access panel, and then replace the
black jumper onto header E49. Replace the access panel and power cord.
If Computrace is enabled on the computer, see the service provider for instruction to disable the feature.
The Real Time Clock (RTC) battery backed-up configuration memory can also be cleared by removing
the power cord and then removing the coin cell battery located on the system board.