HP ProLiant SL160z G6 Server 

Maintenance and Service Guide 

 

 

Part number 571293-005 
Fifth edition March 2011 
 

 

All manuals and user guides at all-guides.com

all-guides.com

Содержание ProLiant SL160z - G6 Server

Страница 1: ...HP ProLiant SL160z G6 Server Maintenance and Service Guide Part number 571293 005 Fifth edition March 2011 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...th in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Intel Xeon and Pentium are trademarks of Intel Corporation or its subsidiaries in the United States and other countries All manuals and user guides at all guides...

Страница 3: ...gement 29 Cable Connections 30 Hard Drives 31 System Board Configuration 33 Processor 33 Memory 40 PCI Expansion Cards 42 System Battery 48 System Board Removal and Replacement Procedure 50 Power Supply Unit PSU 52 System Fan 54 Connectors Switches and LEDs 56 Connectors and Components 56 Front Panel Components 56 Rear panel components 57 System board components 58 Jumpers Password and Chassis ID ...

Страница 4: ... Self Test POST 72 POST Error Indicators 72 POST Errors Message Definition 73 POST Related Troubleshooting 74 Physical and Operating Specifications 75 System Unit 75 Index 78 All manuals and user guides at all guides com ...

Страница 5: ...siness day delivery Same day or four hour delivery may be offered at an additional charge where geography permits If assistance is required you can call the HP Technical Support Center and a technician will help you over the telephone HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP In cases where it is required to return the defecti...

Страница 6: ... suivant dans la limite des stocks disponibles et selon votre situation géographique Si votre situation géographique le permet et que vous demandez une livraison le jour même ou dans les 4 heures celle ci vous sera facturée Pour bénéficier d une assistance téléphonique appelez le Centre d assistance technique HP Dans les documents envoyés avec la pièce de rechange CSR HP précise s il est nécessair...

Страница 7: ...giorno lavorativo seguente La consegna nel giorno stesso o entro quattro ore è offerta con un supplemento di costo solo in alcune zone In caso di necessità si può richiedere l assistenza telefonica di un addetto del centro di supporto tecnico HP Nel materiale fornito con una parte di ricambio CSR HP specifica se il cliente deve restituire dei componenti Qualora sia richiesta la resa ad HP del comp...

Страница 8: ...den gegen einen Aufpreis verfügbar Wenn Sie Hilfe benötigen können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen Den Materialien die mit einem CSR Ersatzteil geliefert werden können Sie entnehmen ob das defekte Teil an HP zurückgeschickt werden muss Wenn es erforderlich ist das defekte Teil an HP zurückzuschicken müssen Sie dies innerhalb ein...

Страница 9: ...laborable Si la situación geográfica lo permite se puede solicitar la entrega en el mismo día o en cuatro horas con un coste adicional Si precisa asistencia técnica puede llamar al Centro de asistencia técnica de HP y recibirá ayuda telefónica por parte de un técnico Con el envío de materiales para la sustitución de componentes CSR HP especificará si los componentes defectuosos deberán devolverse ...

Страница 10: ...de eerstvolgende werkdag Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden aangeboden indien dit mogelijk is gezien de locatie Indien assistentie gewenst is belt u een HP Service Partner om via de telefoon technische ondersteuning te ontvangen HP vermeldt in de documentatie bij het vervangende CSR onderdeel of het defecte onderdeel aan HP moet worden geretourneerd Als het def...

Страница 11: ... as condições geográficas permitirem a entrega no mesmo dia ou em quatro horas pode ser feita mediante uma taxa adicional Se precisar de auxílio entre em contato com o Centro de suporte técnico da HP para que um técnico o ajude por telefone A HP especifica nos materiais fornecidos com a peça CSR de reposição se a peça com defeito deve ser devolvida à HP Nos casos em que isso for necessário é preci...

Страница 12: ...Customer self repair 12 All manuals and user guides at all guides com ...

Страница 13: ...Customer self repair 13 All manuals and user guides at all guides com ...

Страница 14: ...Customer self repair 14 All manuals and user guides at all guides com ...

Страница 15: ...Customer self repair 15 All manuals and user guides at all guides com ...

Страница 16: ...charged for the travel and labor costs of this service 2 Optional Parts for which customer self repair is optional These parts are also designed for customer self repair If however you require that HP replace them for you there may or may not be additional charges depending on the type of warranty service designated for your product 3 No Some HP parts are not designed for customer self repair In o...

Страница 17: ...da un centro di assistenza autorizzato Tali parti sono identificate da un No nel Catalogo illustrato dei componenti 1 Mandatory Zwingend Teile die im Rahmen des Customer Self Repair Programms ersetzt werden müssen Wenn Sie diese Teile von HP ersetzen lassen werden Ihnen die Versand und Arbeitskosten für diesen Service berechnet 2 Optional Optional Teile für die das Customer Self Repair Verfahren o...

Страница 18: ...d met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met Nee 1 Mandatory Obrigatória Peças cujo reparo feito pelo cliente é obrigatório Se desejar que a HP substitua essas peças serão cobradas as despesas de transporte e mão de obra do serviço 2 Optional Opcional Peças cuj...

Страница 19: ...Illustrated parts catalog 19 All manuals and user guides at all guides com ...

Страница 20: ... 2GB PC3 10600E 501540 001 Mandatory1 DIMM 2GB PC3 10600R 501533 001 Mandatory1 DIMM 4GB PC3 10600R 501534 001 Mandatory1 DIMM 4GB PC3 8500R 501535 001 Mandatory1 DIMM 8GB PC3 8500R 519201 001 Mandatory1 5 Processors Optional2 Intel Xeon 6c 2 93 GHz 12M 95W 594882 001 Optional2 Intel Xeon 6c 2 8 GHz 12M 95W 586631 001 Optional2 Intel Xeon 6c 2 66 GHz 12M 95W 594884 001 Optional2 Intel Xeon 4c 2 66...

Страница 21: ...equire that HP replace them for you there may or may not be additional charges depending on the type of warranty service designated for your product 3 No Some HP parts are not designed for customer self repair In order to satisfy the customer warranty HP requires that an authorized service provider replace the part These parts are identified as No in the Illustrated Parts Catalog 1 Mandatory Oblig...

Страница 22: ...bzw Nein gekennzeichnet 1 Mandatory Obligatorio componentes para los que la reparación por parte del usuario es obligatoria Si solicita a HP que realice la sustitución de estos componentes tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio 2 Optional Opcional componentes para los que la reparación por parte del usuario es opcional Estos componentes también...

Страница 23: ... adicional dependendo do tipo de serviço de garantia destinado ao produto 3 No Nenhuma Algumas peças da HP não são projetadas para o reparo feito pelo cliente A fim de cumprir a garantia do cliente a HP exige que um técnico autorizado substitua a peça Essas peças estão identificadas com a marca No Não no catálogo de peças ilustrado HP Contact Information For the name of the nearest HP authorized r...

Страница 24: ...tside North America call the nearest HP Technical Support Phone Center For telephone numbers for worldwide Technical Support Centers refer to the HP website at http www hp com Before You Contact HP Be sure to have the following information available before you call HP Technical support registration number if applicable Product serial number Product model name and number Applicable error messages A...

Страница 25: ...d the following items for some procedures T 10 T 15 wrench The following references and software tools may also be used HP ProLiant SL160z G6 Server Support CD IPMI Event Log Diagnostics Software Hardware Configuration Information Electrostatic Discharge Information An electrostatic discharge ESD can damage static sensitive devices or microcircuit Proper packaging and grounding techniques are nece...

Страница 26: ...e sure you understand them before you begin Post installation instructions Observe the following items after installing or removing a server component 1 Be sure all components are installed according to the described step by step instructions 2 Reinstall the rear cage air baffle peripherals and system cables that you have removed 3 Reinstall the top cover 4 Reinstall server into rack 5 Connect all...

Страница 27: ...e equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct co...

Страница 28: ...andby The standby position removes power from most electronics and the drives but some internal circuitry remains active To completely remove all power from the system disconnect all power cords from the server To power down the server 1 Shut down server as directed by the operating system documentation 2 Press the power button to toggle to Standby This places the server in standby mode changing t...

Страница 29: ...the chassis Figure 2 Reinstalling the top cover Cable Management Always follow good cable management practices when working inside the computer Keep cables away from major heat sources like the heat sink Do not jam cables on top of expansion cards or memory modules Printed circuit cards are not designed to withstand excessive pressure Keep cables clear of sliding or moveable parts to prevent cutti...

Страница 30: ... retaining latch attached to the cable end of the connector 2 Grasp the cable end of the connector and pull it straight up CAUTION Always pull the connector NEVER pull on the cable Pulling on the cable could damage the cable and result in a failed power supply Figure 3 Unplugging power cables Cable Connections The following table provides information about switching power supply cable connector la...

Страница 31: ...em Board Designator RJ45 cable connector RJ45 board J1 UID cable connector UID LED J12 Fan connector 1 Fan 1 J7 Fan connector 2 Fan 2 J6 Fan connector 3 Fan 3 J11 Fan connector 4 Fan 4 J10 Hard Drives The Server can accommodate up to 4 hard disks drives 2 in each tray You can install 4 SAS hard drives or 4 SATA hard drives into the server Figure 4 Hard Drive location Item Description 1 SAS SATA Ha...

Страница 32: ... hard drive 1 Slide the HDD carrier latches to unlock the HDD handle 2 Raise the HDD handle 3 Lift the HDD assembly out of the tray Figure 6 Removing the hard drive assembly WARNING Ensure that the system is powered off and all power sources have been disconnected from the server Voltages are present at various locations within the server whenever an AC power source is connected This voltage is pr...

Страница 33: ...t possible server malfunction Figure 7 Processor locations Item Description 1 Processor 1 2 Processor 2 WARNING To reduce the risk of personal injury from hot surfaces allow the heat sink and the processor to cool before touching them To remove the heat sink CAUTION To prevent the heat sink from tilting to one side during installation and removal procedures use a diagonally opposite pattern an X p...

Страница 34: ...the processor to ensure proper thermal bonding between the processor and the heat sink To remove a processor 1 Open the processor locking lever and the processor socket retaining bracket Figure 9 Opening the processor socket retaining bracket 2 Using the processor removal tool remove the processor from the system board a Line up the processor tool ensuring the locking lever graphic on the tool is ...

Страница 35: ...ly rotate the tool and then push in and release the tabs to secure the processor in the tool Figure 11 Securing the processor CAUTION To avoid damage to the processor do not touch the bottom of the processor especially the contact area All manuals and user guides at all guides com ...

Страница 36: ...lly insert the processor into the processor installation tool Handle the processor by the edges only and do not touch the bottom of the processor especially the contact area Figure 12 Inserting the processor All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 37: ...N THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED To avoid damage to the system board Never install or remove a processor without using the processor installation tool Do not touch the processor socket contacts Do not tilt or slide the processor when lowering the processor into the socket 3 Press and hold the tabs on the processor installation tool to separate it from the processo...

Страница 38: ...r The lever should close without resistance Forcing the lever closed can damage the processor and socket requiring system board replacement Figure 15 Closing the processor socket retaining bracket CAUTION To allow heat sink to draw as much heat as possible from the processor base there must be good contact between the heat sink base and the top of the processor To ensure good contact you must appl...

Страница 39: ...the heat sink with excessive grease can also cause the grease to spread over the processor pins or the system board base which can cause electrical shorts that damage the system To install the heat sink CAUTION To prevent overheating or a possible system crash use only a heat sink model specified for the HP ProLiant SL160z G6 server 1 Put the heat sink frame on the CPU socket 2 Properly align the ...

Страница 40: ...acing memory modules For 4P system both physical processors in each node must be of the same type and speed Use 1066 1333 MHz Registered Unbuffered ECC DDR3 Memory Supported DIMM 512Mb 1 GB 2 GB 4GB and 8GB 256GB maximum capacity DDR3 Figure 18 DIMM slots To remove memory module 1 Completely open the holding clips securing the module 2 Gently pull the memory module upward to remove it from the slo...

Страница 41: ... to secure the memory module in place Figure 20 Installing a Memory module CAUTION The memory slots are structured to ensure proper installation If you insert a memory module but it does not fit easily into the slot you may have inserted it incorrectly Double check the orientation of the module and reinsert If the holding clips do not close the module is not inserted correctly NOTE The ProLiant SL...

Страница 42: ...e X16 and one X4 PCIe Riser slots on the system boards Figure 21 PCIe expansion slot location on 160 system board Item Component Designator Component Function 1 PCIe slot PCIe slot Supports X16 PCI Riser Cards 2 PCIe slot PCIe slot Supports X4 PCI Riser Cards All manuals and user guides at all guides com ...

Страница 43: ...re 23 PCIe Riser Card X4 Connectors Location Single Slot PCIe riser card x16 slot To remove the PCIe riser card with the bracket 1 Loosen the screw securing the riser card bracket to the chassis 2 Pull the riser card away together with the bracket All manuals and user guides at all guides com ...

Страница 44: ...he two screws securing the riser card to the bracket 2 Pull the riser card away from the bracket Figure 25 Removing the PCIe riser card To install the PCIe X16 riser card to the bracket 1 Align the riser card with the bracket 2 Fasten the two screws to secure the riser card to the bracket All manuals and user guides at all guides com ...

Страница 45: ...board and then insert the assembly into the slot 2 Fasten the screw to secure the bracket to the chassis Figure 27 Installing the PCIe riser card with bracket Single Slot PCIe riser card x4 slot To remove the PCIe X4 riser card with the cage 1 Remove the two screws securing the PCIe X4 riser card cage to the Chassis 2 Lift the PCIe X4 cage up and away from the Chassis All manuals and user guides a...

Страница 46: ...o the cage 2 Pull the PCIe card out and away from the PCIe X4 cage Figure 29 Removing the Riser Card X4 To install the PCIe riser card to the cage 1 Align the PCIe X4 riser card to the PCIe X4 Cage 2 Install and tighten the two screws that secure the riser card to the riser card cage All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 47: ...Install and tighten the two screws to secure the riser card cage to the chassis Figure 31 Reinstalling the PCIe Riser Card X4 To remove the PCIe card 1 Remove the screw that secures the PCIe card 2 Open the PCIe latch 3 Pull the PCIe card back and away from the PCIe riser card 4 Slide the PCIe bracket across the chassis 5 Close the PCIe latch All manuals and user guides at all guides com ...

Страница 48: ... the PCIe card into riser card connector 4 Close PCIe latch 5 Install screws Figure 33 Installing the PCIe card System Battery The server uses nonvolatile memory that requires 2 batteries to retain system information when power is removed This 3 volt lithium coin cell battery is located on the system board All manuals and user guides at all guides com ...

Страница 49: ...o manufacturer s instructions CAUTION Loss of BIOS settings occurs when the battery is removed You must reconfigure BIOS settings whenever you replace the battery NOTE If the server no longer automatically displays the correct date and time you may need to replace the system battery Under normal usage battery life is five to ten years To replace the system battery 1 To release the battery from its...

Страница 50: ...Press the tray latch to release the tray handle 2 Rotate the tray handle to disengage the power connector 3 Pull the tray assembly out of the chassis Figure 36 Removing the tray with system board Remove the system board from the tray 1 Remove the nine screws that secure the system board to the tray 2 Release the system board from the tray All manuals and user guides at all guides com ...

Страница 51: ...s should align with the system board 2 Fasten the nine screws on the system board to secure the system board to the chassis Figure 38 Reinstalling the160 system board to the tray To replace the tray with system board 1 Push the tray assembly into the tray bay until it stops 2 Rotate the tray handle until the tray latch catches All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 52: ...of personal injury from electric shock hazards and or damage to the equipment Installation of power supply units should be referred to individuals who are qualified to service server systems and are trained to deal with equipment capable of generating hazardous energy levels DO NOT open the power supply unit There are no serviceable parts inside it To install the power supply 1 Remove the power su...

Страница 53: ...Figure 41 Installing the Power supply 1 Figure 42 Installing the power supply 2 To remove the power supply 1 Press the blue colored handle 2 Slide the power supply out of the power supply cage 3 Install the power supply blank into the place where power supply was seated All manuals and user guides at all guides com ...

Страница 54: ...ption Installation instructions for details The figure below identifies the system fans by their device number and shows their corresponding cable connections Figure 44 System fan connection Device number Connector System fan 1 J6 on the AC power board System fan 2 J8 on the AC power board System fan 3 J10 on the AC power board System fan 4 J11 on the AC power board All manuals and user guides at ...

Страница 55: ...he system fan 1 Disconnect the fan cable from its corresponding board connector 2 Lift the system fan away from the chassis Figure 45 Removing the system fan To replace the system fan 1 Insert the system fan into the fan bracket 2 Connect the fan cable to its corresponding board connector Figure 46 Installing the system fan All manuals and user guides at all guides com ...

Страница 56: ... panel system board and hard drives of the HP ProLiant SL160z G6 Connectors and Components Front Panel Components Figure 47 Front panel components Item Description 1a Tray handle 1b Tray latch 2 Serial Port 3 Video Port 4 Top USB 2 0 Port Bottom USB 2 0 Port 5 Top NIC Connector Bottom NIC Connector 6 IPMI Port 7 UID LED SW 8 PCI blank 9 Health LED All manuals and user guides at all guides com a l ...

Страница 57: ...s and LEDs 57 Item Description 10 Power Button Rear panel components Figure 48 Rear panel components Item Description 1 RJ45 port 2 Power supply 2 3 Power supply 1 4 UID LED All manuals and user guides at all guides com ...

Страница 58: ...J2 Serial Port COM1 2 J1 VGA port 3 J8 USB PORT 4 J7 NIC Port 5 J21 J22 J79 J23 J24 J78 J25 J26 J77 MEMORY DIMM CONN 6 SW1 UID BUTTON 7 J90 IPMI CONN 8 J18 PCIE X4 LP RISER SLOT 9 J17 PCIE X16 FH FL RISER SLOT A 10 J27 Jumper 11 J29 TPM CONN 12 J31 PCIE X4 FH FL RISER SLOT B All manuals and user guides at all guides com ...

Страница 59: ...t to remove an installed TPM from the system board breaks or disfigures the TPM security rivet Upon locating a broken or disfigured rivet on an installed TPM administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data If you suspect a TPM board failure leave the TPM installed and remove the system board Contact an HP authorized ser...

Страница 60: ...toring of basic system functions while the server is operating Figure 50 Health LED Indicator location Table 5 Health LED indicator status Components Status Description Health LED indicator for Node 1 Red Blinking Critical system failure detected Amber Blinking System degrade Green System in on and no failure detected Off System is off and there is no failure prior to system power off Health LED i...

Страница 61: ...e name here Components Status Descriptions UID LED indicator for Node 1 Blue Identification Blue Blinking System is being remotely managed Off Off UID LED indicator for Node 2 Blue Identification Blue Blinking System is being remotely managed Off Off Power LED Indicator The power status of the server is indicated by the bicolor LED on the front panel All manuals and user guides at all guides com a...

Страница 62: ...o the server Please refer to SEL for details Off The server is system off without A C power Power LED indicator for Node 2 Steady green The server is operating normally Steady Amber The server is system off or in hibernation with A C power Steady red Critical event happens to the server Please refer to SEL for details Off The server is system off without A C power Rear panel LED indicators The LAN...

Страница 63: ...1 LAN activity status LED indicator Flashing green Ongoing network data activity Off No network data activity or no connection 2 LAN network speed LED indicator Steady green The LAN connection is using a GbE link Steady amber The LAN connection is using 10Mbps 100 Mbps link Off No connection All manuals and user guides at all guides com ...

Страница 64: ...edirection PXE boot and much more Initialize hardware at boot up using POST routines During power on or warm reset the BIOS perform Power on Self Test POST routines to test system components to allocate resource for various hardware devices and to prepare the system to boot to various operating systems BIOS Setup Utility The HP server BIOS Setup Utility is used to configure five primary menu selec...

Страница 65: ...user configurable for one of the following reasons The field value is auto configured or auto detected The field value is informational only The field is password protected Enter To select a field value or display a submenu screen Displays more option for items marked with Esc If you press this key On one of the primary menu screens the Exit menu displays On a submenu screen the previous screen di...

Страница 66: ... BIOS Setup Utility provides a menu bar with the menu selections The menu bar choices are described in the topics below Main Menu Figure 55 Main menu of BIOS Setup Utility Use this menu to set the system time and date and configure of the following items View BIOS build date and version All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 67: ...You can use this screen to select options for the CPU Configuration Settings Use the up and down Arrow keys to select an item Use the Plus and Minus keys to change the value of the selected option A description of the selected item appears on the right side of the screen The settings are described on the following pages CPU Bridge Configuration You can use this screen to select options for the CPU...

Страница 68: ...keys to change the value of the selected option BIOS Serial Console Configuration Set this value to allow configuring the serial port Trusted Computing Configure settings related to trusted Computing innovations Figure 57 IPMI Configuration menu of the BIOS Setup Utility Set LAN Configuration Select Set LAN Configuration in the left frame of the screen to go to the submenu for that item You can di...

Страница 69: ...ort Configuration in the left frame of the screen to go to the submenu for that item Then you can press Enter to enter its submenu You can display a submenu about Serial Port Configuration option by highlighting it using the Arrow keys Security Menu Figure 58 Security menu of the BIOS Setup Utility 1 Figure 59 Security menu of the BIOS Setup Utility 2 Use this menu to configure the following items...

Страница 70: ...en press Enter 5 Press F10 to close the Setup Utility 6 After setting the password Setup automatically sets the password check to Setup Boot Menu Figure 60 Boot menu of the BIOS Setup Utility Use this menu to configure the boot settings Boot Setting Configuration Sets which options to run during system boot up Press Enter to access the related submenu For details on the submenu options see the Boo...

Страница 71: ...OS setup fields BIOS Update Perform the steps below to update BIOS 1 Download the Smart Component SPxxxxx exe to a directory on your hard drive 2 Execute SPxxxxx exe and followed with direction to complete the steps ProLiant Flash Update interface will appear 3 Select items which need to execute Create a bootable ROMPaq diskette Create a bootable ROMPaq USB Key Create a bootable ROMPaq CD ROMPaq D...

Страница 72: ... server all devices must be tested and initialized and the operating system must be bootstrapped to the memory This is referred to as Power on Self Test or POST POST is a series of diagnostic tests that checks firmware and hardware components on the system to ensure that the server is properly functioning This diagnostic function automatically runs each time the server is powered on These diagnost...

Страница 73: ...an Configuration One Fan Failure or Missing 622 Redundant Fan Configuration Multiple Fans Failure or Missing 623 Temperature Violation Detected Waiting 5 minutes for system to cool Press ESC Key to resume booting without waiting for the system to cool Warning Pressing ESC is NOT recommended as the system may shutdown unexpectedly 624 Power Supply Failure or Power Supply Unplugged 626 Update SDRR C...

Страница 74: ...e is during a routine boot up check the following All external cables and power cables should be firmly plugged in The power outlet to the server should be connected and works correctly The server and monitor are both turned on The bicolour status LED indicator on the front panel must be lit up green The monitor s contrast and brightness settings are correct All internal cables are properly connec...

Страница 75: ...lersburg36D SATA and IDE controllers Intel ICH10R Embedded video controller ServerEngines VGA core integrated into Pilot II I O subsystem PCIE x24 links slot For X16 PCIE 1U riser X16 x4 x4 2U riser X8 x8 x8 2U riser X16 x8 2U riser Memory Six REG DDR3 800 1066 1333 MHz DIMM slots with ECC Support RDIMM and UDIMM Default media storage SAS SATA hard drive Optional media storage Eight bays hot plug ...

Страница 76: ...latform ATX Advanced Technology Extended System board dimension 17 935 x6 5 Server dimensions Rack 448W X87 5H X 735 5D mm Server weight Basic Configuration excludes keyboard and monitor 20 kg Table 13 Environmental Specifications Item Description Temperature Operating Non operating Storage Wet bulb temperature 10 to 35 50 to 95 F 30 to 60 22 to 140 F 30 to 60 22 to 140 F 38 7 101 7 F Relative hum...

Страница 77: ... x 86 36 mm x 190 52 mm Weight approximate 1 1 kg Input requirements Rated input voltage Normal line voltage 90 VAC to 264 VAC 100 VAC to 120 VAC 200 VAC to 240 VAC Line frequency 50Hz 60Hz Rated input current Max 10A BTU rating N A Power supply output power Rated steady state power Maximum peak power 460W 750W 1200wW N A Temperature range Operating Storage Shipping 5 to 50 40 to 85 Relative humid...

Страница 78: ... 32 memory 41 PCI expansion cards 43 power supply unit 53 processor 34 references 25 system battery 49 system fan 55 top cover 28 Hardware configuration tools 25 hardware specifications I O ports 76 LAN controller 76 memory 76 power supply unit 77 processor socket 76 processor support 76 status LED indicators 77 thermal solution 77 Hardware Specifications chipset 76 default media storage 76 Hardwa...

Страница 79: ...ee PSU Power system health LED indicator 62 Power On Self Test POST error indicators 73 POST related troubleshooting 75 recoverable POST errors 74 processor applying thermal grease 40 installing 40 removing 36 Processor heat sink spare part number 21 processor socket specification 76 Processors spare part number 20 PSU removing 53 replacement warnings 53 type 77 R Rail kit left spare part number 1...

Страница 80: ...cations 76 T thermal solution 77 top cover reinstalling 29 removing 28 Top cover spare part number 16 Tray with system board removing 51 replacing 52 W warnings battery replacement 50 PSU replacement 53 warranty 5 All manuals and user guides at all guides com ...