Illustrated parts catalog 21
Item Description
Spare part number
Customer self repair
a) 1.70 GHz Intel Xeon E5-2603 v4, 6C,
85 W*
835599-001
Optional
2
b) 1.70 GHz Intel Xeon E5-2609 v4, 8C,
85 W*
835600-001
Optional
2
c) 1.70 GHz Intel Xeon E5-2650L v4,
14C, 65 W*
835609-001
Optional
2
d) 1.80 GHz Intel Xeon E5-2630L v4,
10C, 55 W*
835608-001
Optional
2
e) 2.00 GHz Intel Xeon E5-2660 v4, 14C,
105 W*
835605-001
Optional
2
f) 2.10 GHz Intel Xeon E5-2620 v4, 8C,
85 W*
835601-001
Optional
2
g) 2.10 GHz Intel Xeon E5-2683 v4, 16C,
120 W*
835614-001
Optional
2
h) 2.10 GHz Intel Xeon E5-2695 v4, 18C,
120 W*
835615-001
Optional
2
i) 2.20 GHz Intel Xeon E5-2630 v4, 10C,
85 W*
835602-001
Optional
2
j) 2.20 GHz Intel Xeon E5-2650 v4, 12C,
105 W*
835604-001
Optional
2
k) 2.20 GHz Intel Xeon E5-2697A v4, 16c,
145 W*
841035-001
Optional
2
l) 2.20 GHz Intel Xeon E5-2698 v4, 20c,
135 W*
835617-001
Optional
2
m) 2.20 GHz Intel Xeon E5-2699 v4, 22c,
145 W*
835618-001
Optional
2
n) 2.30 GHz Intel Xeon E5-2697 v4, 18c,
145 W*
835616-001
Optional
2
o) 2.40 GHz Intel Xeon E5-2680 v4, 14C,
120 W*
835606-001
Optional
2
p) 2.60 GHz Intel Xeon E5-2623 v4, 4C,
85 W*
835610-001
Optional
2
q) 2.60 GHz Intel Xeon E5 2690 v4, 14c,
135 W
835607-001
Optional
2
r) 2.90 GHz Intel Xeon E5-2667 v4, 8c,
135 W*
835613-001
Optional
2
s) 3.20 GHz, Intel Xeon E5-2643 v4, 6c,
135W*
835612-001
Optional
2
t) 3.40 GHz Intel Xeon E5-2637 v4, 4c,
135 W*
835611-001
Optional
2
15
Heatsink
780977-001
Optional
2
16
x4-slot power supply backplane
780969-001
Optional
2
17
x2-slot power supply backplane
780968-001
Optional
2
18
Power supplies
—
—
a) 500W Flex Slot Platinum hot-plug
power supply
754377-001
Mandatory
1
b) 800W Flex Slot Platinum hot-plug
power supply*
754381-001
Mandatory
1
c) 800W Flex Slot Universal hot-plug
power supply*
754379-001
Mandatory
1
d) 800W Flex Slot -48VDC hot-plug
power supply*
754382-001
Mandatory
1
e) 800W Flex Slot Titanium hot-plug
power supply*
754378-001
Mandatory
1
f) 1400W Flex Slot Platinum hot-plug
power supply*
754383-001
Mandatory
1
Содержание ProLiant ML350 Gen9
Страница 5: ...Contents 5 Index 123 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 18: ...Illustrated parts catalog 18 ...
Страница 64: ...Removal and replacement procedures 64 LFF configuration SFF configuration ...
Страница 91: ...Component identification 91 o Rack orientation 24 LFF drives o Tower orientation ...
Страница 104: ...Cabling 104 Storage controller installed in slot 1 to 4 Storage controller installed in slot 6 to 9 ...
Страница 105: ...Cabling 105 HPE Smart Storage Battery cabling Power supply backplane cabling GPU power cabling ...
Страница 109: ...Cabling 109 Embedded SATA cabling LFF configuration SFF configuration ...
Страница 112: ...Cabling 112 o SFF configuration o LFF configuration SAS Expander cabling One SAS Expander ...
Страница 113: ...Cabling 113 o LFF configuration o SFF configuration ...
Страница 114: ...Cabling 114 Two SAS Expanders Express bay cabling Express bay bridge card installed in PCIe slot 3 ...