Hardware options installation 38
14.
Install the heatsink.
15.
Install the air baffle (on page
24
).
16.
Install any full-length expansion boards, if previously removed.
17.
Install the access panel (on page
20
).
18.
Install the server into the rack ("
Installing the server into the rack
" on page
30
).
19.
Connect each power cord to the server.
20.
Connect each power cord to the power source.
Memory options
IMPORTANT:
This server does not support mixing LRDIMMs, RDIMMs, or UDIMMs. Attempting
to mix any combination of these DIMMs can cause the server to halt during BIOS initialization.
The memory subsystem in this server supports LRDIMMs and RDIMMs:
•
UDIMMs are not supported in this server.
•
RDIMMs offer larger capacities than UDIMMs and include address parity protection.
•
LRDIMMs support higher densities than single- and dual-rank RDIMMs, and higher speeds than
quad-rank RDIMMs. This support enables you to install more high capacity DIMMs, resulting in higher
system capacities and higher bandwidth.
All types are referred to as DIMMs when the information applies to all types. When specified as LRDIMM or
RDIMM, the information applies to that type only. All memory installed in the server must be the same type.
The server supports the following DIMM speeds:
Содержание ProLiant DL560 Gen8
Страница 65: ...Cabling 65 Cabling SAS drive cabling ...
Страница 94: ...Support and other resources 94 ...
Страница 95: ...Support and other resources 95 ...