Hardware options installation 63
9.
Install the TPM security rivet by pressing the rivet firmly into the system board.
10.
Install the air baffle (on page
24
).
11.
Install the PCI riser cage ("
Install the primary PCIe riser cage
" on page
22
).
12.
Install the access panel (on page
20
).
13.
Install the server into the rack ("
Installing the server into the rack
" on page
30
).
14.
Connect each power cord to the server.
15.
Connect each power cord to the power source.
16.
Power up the server (on page
18
).
Retaining the recovery key/password
The recovery key/password is generated during BitLocker™ setup, and can be saved and printed after
BitLocker™ is enabled. When using BitLocker™, always retain the recovery key/password. The recovery
key/password is required to enter Recovery Mode after BitLocker™ detects a possible compromise of system
integrity.
To help ensure maximum security, observe the following guidelines when retaining the recovery
key/password:
•
Always store the recovery key/password in multiple locations.
•
Always store copies of the recovery key/password away from the server.
•
Do not save the recovery key/password on the encrypted hard drive.
Enabling the Trusted Platform Module
1.
When prompted during the start-up sequence, access RBSU by pressing the
F9
key.
2.
From the Main Menu, select
Server Security
.
3.
From the Server Security Menu, select
Trusted Platform Module
.
4.
From the Trusted Platform Module Menu, select
TPM Functionality
.
5.
Select
Enable
, and then press the
Enter
key to modify the TPM Functionality setting.