Prerequisites
The 12G SAS Expander Card supports up to 24 SFF drives, depending on which options are also installed in
the server.
The following components must be installed:
• Storage controller
• Drive cages
◦ 24SFF drive configuration—Bay 1, bay 2, and bay 3 installed with 8SFF front drive cages
◦ 18SFF drive configuration—Bay 1 Universal Media Bay installed with 2SFF drive cage option, and bay
2 and bay 3 installed with 8SFF front drive cages.
◦ 16SFF drive configuration—Bay 2 and bay 3 installed with 8SFF drive cages
Procedure
1.
on page 38).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
• Extend the server from the rack (
Extend the server from the rack
on page 38).
• Remove the server from the rack (
Removing the server from the rack
4.
on page 40).
5.
If installed, do the following:
a.
Remove the air baffle (
on page 42).
b.
Remove the processor mezzanine tray (
Removing the processor mezzanine tray
on page 47).
c.
Remove the joint board (
Removing the 2P pass-through performance board
on page 48).
d.
Remove the 2P pass-through performance board (
Removing the 2P pass-through performance
on page 48).
6.
on page 46).
7.
Remove the primary PCIe riser cage (
on page 44).
8.
Remove the expansion slot blank from slot 2.
9.
Using the labels on the cables to determine the correct connections, connect the cables to the SAS
expander card.
a.
Depending on the ports on the controller, connect the appropriate controller cables to the SAS
expander card.
b.
Depending on the drive configuration, connect the appropriate drive cage cables to the SAS expander
card.
Installing hardware options
97
Содержание ProLiant DL560 Gen10
Страница 9: ...Eight bay SFF NVMe drive cage Two bay NVMe Six bay SFF HDD drive cage Component identification 9 ...
Страница 29: ...Item Description 1 x8 Slimline NVMe connector 2 x8 Slimline NVMe connector Component identification 29 ...
Страница 65: ...2 Prepare the drive 3 Install the drive 4 Observe the LED status of the drive Installing hardware options 65 ...
Страница 100: ... 18 SFF backplanes Group C SAS cables 100 Installing hardware options ...
Страница 101: ... 16 SFF backplanes Group C SAS cables Installing hardware options 101 ...
Страница 111: ...Connected to the system board SATA ports 1 and 2 Connected to the HPE P816i a Smart Array controller Cabling 111 ...
Страница 113: ...Connected to the secondary PCIe riser board Connected to the tertiary PCIe riser board Cabling 113 ...
Страница 114: ...Connected to the system board SATA ports 1 and 2 Connected to the Smart Array controller 114 Cabling ...
Страница 115: ...Drive box 3 cabling Connected to the Primary PCIe riser board Connected to the secondary PCIe riser board Cabling 115 ...
Страница 116: ...Connected to the system board SATA ports 1 and 2 Connected to an HPE Smart Array controller 116 Cabling ...
Страница 119: ...Quad slimline riser installed in the secondary PCIe riser cage Tertiary riser Cabling 119 ...