RBSU menu (HP ProLiant G6 and earlier servers or server blades) 129
BIOS Enhanced RAID
The BIOS Enhanced RAID feature is a toggle setting that, when enabled, analyzes the Linux data on
installed hard drives for failure information. Based on the analysis, the system ROM automatically chooses
which hard drive to boot.
Node Interleaving
The Node Interleaving feature requires all nodes to have equal memory sizes when enabled. Enabling
Node Interleaving may affect OS performance.
Serial Number
The Serial Number option allows you to change the serial number. HP recommends that you do not
change this number, unless you are replacing a system board. When the Serial Number option is chosen,
a warning displays:
The serial number should ONLY be modified by qualified service
personnel. This value should always match the serial number located on
the chassis.
Product ID
The Product ID option sets the system product ID, which is found on the product ID sticker on the chassis.
When the Product ID option is chosen, a warning displays:
The Product ID should ONLY be modified by qualified service personnel.
This value should always match the Product ID located on the chassis.
Drive Write Cache
The Drive Write Cache option controls the state of the write cache of the drives attached to the supported
controller. When the Drive Write Cache option is chosen, a warning displays:
Enabling Drive Write Cache may result in data loss or data corruption if
an unexpected power loss occurs.
SATA Software RAID
The SATA Software RAID feature enables RAID functionality (RAID 0 or RAID 1) for the embedded SATA
controller in the system. When the SATA Software RAID option is chosen, a warning displays:
Enabling Software RAID will result in data loss or data corruption on
existing SATA drives. Please backup all drives before enabling this
feature.
Optional PCI-X Riser Fan Monitoring
The Optional PCI-X Riser Fan Monitoring option, disabled by default, enables fan monitoring when an
optional PCI-X expansion cage is installed.
Содержание ProLiant DL380e
Страница 1: ...HP ROM Based Setup Utility User Guide Part Number 347563 402 September 2010 Eleventh Edition ...
Страница 22: ...RBSU menu HP ProLiant G7 servers or server blades 22 The default setting is Enabled ...
Страница 26: ...RBSU menu HP ProLiant G7 servers or server blades 26 The default setting is Enabled ...
Страница 37: ...RBSU menu HP ProLiant G7 servers or server blades 37 Disabled ...
Страница 44: ...RBSU menu HP ProLiant G7 servers or server blades 44 Disabled ...
Страница 52: ...RBSU menu HP ProLiant G7 servers or server blades 52 5 minutes ...
Страница 90: ...RBSU menu HP ProLiant G7 servers or server blades 90 Disabled ...
Страница 95: ...RBSU menu HP ProLiant G7 servers or server blades 95 Disabled ...