Removal and replacement procedures 51
* Fan redundancy is not supported for processors exceeding 105 W.
•
In the redundant fan mode:
o
If one fan rotor fails, the system continues to operate without redundancy. This condition is
indicated by a flashing amber Health LED.
o
If two fan rotors fail, the operating system shuts down.
Fan blank
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To prevent damage to electrical components, take the appropriate anti-static
precautions before beginning any system installation. Improper grounding can cause
electrostatic discharge.
CAUTION:
To prevent improper cooling and thermal damage, do not operate the chassis
unless all bays are populated with a component or a blank.
To remove the component:
1.
Power down the server (on page
30
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Disconnect all peripheral cables and power cords from the rear panel.
4.
Do one of the following:
o
Extend the server from the rack (on page
30
).
o
Remove the server from the rack (on page
33
).
5.
Remove the access panel ("
Access panel
" on page
40
).
6.
Remove the air baffle (on page
34
).
7.
Remove the fan blank.
Содержание ProLiant DL120 Gen9
Страница 5: ...Contents 5 Documentation feedback 117 Index 118 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 26: ...Illustrated parts catalog 26 ...
Страница 36: ...Removal and replacement procedures 36 o Secondary PCI riser cage o PCI blank ...
Страница 116: ...Acronyms and abbreviations 116 UID unit identification USB universal serial bus ...