Memory configuration
To optimize server availability, the server supports ECC memory. ECC memory provides the greatest memory
capacity for a given DIMM size, while providing single-bit memory error corrections, depending on the
specific DIMM type. This mode is the default option for this server.
For the latest memory configuration information, see the QuickSpecs on the HP website
(
http://www.hp.com
).
ECC memory configuration
ECC memory is the default memory protection mode for this server. Standard ECC can correct single-bit
memory errors and detect multi-bit memory errors. When multi-bit errors are detected by using Standard
ECC, the error is sent to the server and causes the server to halt.
General DIMM slot population guidelines
•
The server has four memory slots.
•
The server supports two channels with two UDIMM slots per channel.
•
Memory channel A consists of the two UDIMMs that are closest to the processor.
•
Memory channel B consists of the two UDIMMs that are located farthest from the processor.
•
Different types of processors have different types of memory support.
•
The server supports dual-rank, 1,333 MT/s ECC UDIMMs.
•
The server supports up to 32 GB (4x8-GB) for UDIMMs.
•
The server does not support:
o
LV-DIMMs
o
RDIMMs
o
Non-ECC UDIMMs
•
When installing DIMMs:
o
If the processor is not installed, then do not install DIMMs.
o
Populate DIMMs from heaviest load (double-rank) to lightest load (single-rank).
o
Use HP-qualified UDIMMs.
o
The DIMM farthest from the processor (either CHA or CHB) must be populated first.
Installing a DIMM
NOTE:
The server does not support Elpida UDIMM memory.
1.
Power down the server (on page
17
).
2.
Remove the access panel (on page
18
).
3.
Remove the air baffle (on page
19
).
4.
Open the DIMM slot latches.
Содержание ProLiant DL120 G7
Страница 21: ...Operations 21 2 Install the access panel on page 18 3 Power up the server on page 17 ...
Страница 41: ...Hardware options installation 41 10 Remove the rear bracket 11 Remove the ATX power supply ...
Страница 49: ...Cabling 49 RPS cabling Internal USB cabling ...
Страница 51: ...Cabling 51 ODD cabling SATA cabling LFF model ...
Страница 52: ...Cabling 52 SFF model SAS cabling LFF model ...
Страница 53: ...Cabling 53 SFF model ...
Страница 74: ...Troubleshooting 74 ...
Страница 97: ...Support and other resources 97 ...
Страница 98: ...Support and other resources 98 ...
Страница 101: ...Acronyms and abbreviations 101 UID unit identification USB universal serial bus VCA Version Control Agent ...