2.
If you intend to con
fi
gure a remote server, con
fi
rm that the ACU Execution Mode is set to remote
service.
3.
Open the browser, either locally (on the host) or on the remote server.
4.
Enter the following text into the browser address
fi
eld (where
servername
is the name or IP address of
the host):
http://servername:2301
The login screen for the System Management homepage opens.
5.
Log in. The System Management homepage opens.
6.
Click
Array Con
fi
guration Utility
on the left side of the window. The ACU opens and identi
fi
es the
controllers that are connected to the system. This process could take a minute or two.
Some ACU guidelines to consider:
•
Do not modify Array A off of the Smart Array controller, because it contains the storage server
operating system.
•
Spanning more than 14 disks with a RAID 5 volume is not recommended.
•
Designate spares for RAID sets to provide greater protection against failures.
•
RAID sets cannot span controllers.
•
A single array can contain multiple logical drives of varying RAID settings.
•
Extending and expanding arrays and logical drives is supported.
•
RAID migration is not supported.
The
HP Array Con
fi
guration Utility User Guide
is available for download at
h200002.www2.hp.com/bc/docs/support/SupportManual/c00294139/c00294139.pdf
HP Storage Manager
The HP Storage Manager supports the SATA RAID controller and SATA hard disk drives installed
on the storage server.
NOTE:
Not all SATA-based storage servers use hardware RAID with the HP Storage Manager.
52
File server management
Содержание ProLiant DL100 G2 DPSS
Страница 12: ...12 ...
Страница 18: ...18 About this guide ...
Страница 26: ...26 The HP storage server solution ...
Страница 46: ...46 Storage management overview ...
Страница 134: ...134 Troubleshooting servicing and maintenance ...
Страница 152: ...152 Regulatory compliance and safety ...