2.
On the storage server, open Device Manager, right-click on the EVA LUN and select
Scan for
hardware changes
.
3.
Open a command prompt and run
DiskPart.exe
.
4.
List the current volumes of the system (List Volumes).
5.
Select the volume to be extended (select volume X).
6.
Extend the volume (extend [size=n]). Size is optional.
Expanding storage using the Array Con
fi
guration Utility
The Array Con
fi
guration Utility enables online capacity expansion of the array and logical drive for
speci
fi
c MSA storage arrays, such as the MSA1000 and MSA1500.
Expand array
Expanding an existing LUN is accomplished using the storage array con
fi
guration software applicable to
the storage array in use. In case of the Smart Array controller, this is accomplished by using the Array
Con
fi
guration Utility. LUN expansion may occur in disk arrays where space is available. If insuf
fi
cient
space is available, additional physical disks may be added to the array dynamically.
IMPORTANT:
An array expansion, logical drive extension, takes about 15 minutes per gigabyte, or considerably
longer if the controller does not have a battery-backed cache. While this process is occurring, no other
expansion or extension can occur simultaneously on the same controller.
HP ProLiant DL100 G2 Storage Server administration guide
59
Содержание ProLiant DL100 G2 DPSS
Страница 12: ...12 ...
Страница 18: ...18 About this guide ...
Страница 26: ...26 The HP storage server solution ...
Страница 46: ...46 Storage management overview ...
Страница 134: ...134 Troubleshooting servicing and maintenance ...
Страница 152: ...152 Regulatory compliance and safety ...