![HP ProLiant DL G6 Скачать руководство пользователя страница 119](http://html.mh-extra.com/html/hp/proliant-dl-g6/proliant-dl-g6_user-manual_164639119.webp)
Software and configuration utilities 119
3.
Select
System Options
.
4.
Select
Advanced Memory Protection
.
5.
Select
Mirrored Memory with Advanced ECC Support
.
6.
Press the
Enter
key.
7.
Press the
Esc
key to exit the current menu or press the
F10
key to exit RBSU.
For more information on mirrored memory, see the white paper on the HP website
(
http://h18000.www1.hp.com/products/servers/technology/memoryprotection.html
).
Configuring Advanced ECC memory
To configure Advanced ECC memory:
1.
Install the required DIMMs ("
Installing a DIMM
" on page
52
).
2.
When the prompt appears, access RBSU by pressing the
F9
key during power-up.
3.
Select
System Options
.
4.
Select
Advanced Memory Protection
.
5.
Select
Advanced ECC Memory
.
6.
Press the
Enter
key.
7.
Press the
Esc
key to exit the current menu or press the
F10
key to exit RBSU.
For more information on Advanced ECC, see the HP website
(
http://h18000.www1.hp.com/products/servers/technology/memoryprotection.html
).
Configuring lockstep memory
To configure Lockstep memory:
1.
Install the required DIMMs ("
Installing a DIMM
" on page
52
).
2.
Access RBSU by pressing the
F9
key during power-up when the prompt is displayed.
3.
Select
System Options
.
4.
Select
Advanced Memory Protection
.
5.
Select
Lockstep with Advanced ECC Support
.
6.
Press the
Enter
key.
7.
Press the
Esc
key to exit the current menu, or press the
F10
key to exit RBSU.
For more information on Lockstep memory, see the white paper on the HP website
(
http://h18000.www1.hp.com/products/servers/technology/memoryprotection.html
).
Array Configuration Utility
ACU is a browser-based utility with the following features:
•
Runs as a local application or remote service
•
Supports online array capacity expansion, logical drive extension, assignment of online spares, and
RAID or stripe size migration
•
Suggests the optimum configuration for an unconfigured system
Содержание ProLiant DL G6
Страница 32: ...Operations 32 3 Remove the hard drive cage blank ...
Страница 92: ...Hardware options installation 92 o Rear 1 o Front 2 19 Remove the chassis from the tower side panels ...
Страница 106: ...Cabling 106 Six bay LFF backplane cabling Drive cage bay 1 Drive cage bay 2 ...
Страница 107: ...Cabling 107 Eight bay SFF drive cage cabling Drive cage bay 1 Drive cage bay 2 ...
Страница 110: ...Cabling 110 DVD ROM drive cabling Slimline optical drive cabling ...
Страница 115: ...Cabling 115 BBWC battery pack and FBWC capacitor pack cabling ...
Страница 138: ...Troubleshooting 138 ...
Страница 164: ...Technical support 164 ...
Страница 165: ...Technical support 165 ...