Troubleshooting
Table D-4: Is the Server Blade Internal Health LED Solid Green?
continued
Answer Possible
Reasons Possible
Solutions
No, it is flashing
green.
The server blade is still in POST.
If the flashing continues after
2.5 minutes, one of the following
conditions may apply:
•
No bootable devices exist,
and the server blade is not
connected to the PXE
network.
•
A SCSI hard drive with an
operating system is not
installed properly, or is not
functioning.
Wait for the server blade to complete
POST.
Be sure a SCSI hard drive is available
with an operating system installed
properly.
Be sure that a connection exists to either
a bootable device or to the PXE
deployment server. Refer to “Network-
Based PXE Deployment” in Chapter 2 for
details.
Clear the system configuration. Refer to
the “Clearing the System Configuration”
section in this appendix.
Switch to the redundant ROM. Refer to
the “Accessing the Redundant ROM”
section in this appendix.
If the internal health LED is still not solid
green, perform one of the following
actions:
•
Use the iLO remote console to
continue the diagnosis.
•
Use the I/O cable connectors,
depending on the server blade
model, to continue diagnosis.
•
Use the iLO system status page to
help determine the problem.
•
Contact an authorized service
provider for replacement parts and
service.
continued
D-8
HP ProLiant BL40p Server Blade Setup and Installation Guide
HP CONFIDENTIAL
Writer: Amy Clute File Name: g-appd Troubleshooting.doc
Codename: Black Ice Part Number: 307153-002 Last Saved On: 11/11/03 2:35 PM