Control panel message
Description
Recommended action
2.
If the error persists and system BIOS has
been recently updated, restore previous
system BIOS version. Otherwise, update
the ME firmware version.
3.
If the error still persists, replace the
system board.
2230-General error during MEBx execution
Error occurred during MEBx execution which
fails into the “General” grouping. Status
information displayed along with the error
provides further clarity into the failure. MEBx
handles transference of information between
the system BIOS and ME firmware.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
2231-ME error during MEBx execution
Error occurred during MEBx execution which
fails into “ME” grouping.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
2232-AMT error during MEBx execution
Error occurred during MEBx execution which
fails into “AMT” grouping.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
2233-HECI error during MEBx execution
Error occurred during MEBx execution which
fails into “MEI or HECI” grouping.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
2239-ME image lock failure
Special system configurations with reduced ME
firmware image require BIOS control of ME
firmware upgrading. A failure has occurred
after the ME firmware update process in which
the BIOS could not relock the ME firmware
region.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
2240-ME image unlock failure
Special system configurations with reduced ME
firmware image require BIOS control of ME
firmware upgrading. A failure has occurred
prior to the ME firmware update process in
which the BIOS could not unlock the ME
firmware region.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
Invalid Electronic Serial Number
Electronic serial number is missing.
Enter the correct serial number in Computer
Setup.
Network Server Mode Active and No Keyboard
Attached
Keyboard failure while Network Server Mode
enabled.
1.
Reconnect keyboard with computer
turned off.
2.
Check connector for bent or missing pins.
3.
Ensure that none of the keys are
depressed.
122 Chapter 8 POST error messages
Содержание ProDesk 400 G2
Страница 4: ...iv Safety warning notice ...
Страница 9: ...Appendix B Statement of Volatility 144 Appendix C Specifications 146 Index 148 ix ...
Страница 10: ...x ...