![HP ProCurve 1600M Скачать руководство пользователя страница 471](http://html.mh-extra.com/html/hp/procurve-1600m/procurve-1600m_management-and-configuration-manual_155305471.webp)
Redundancy (Switch 8212zl)
Event Log Messages
#
System Message
Severity
Description
268
Mgmt Module [1 or 2] - Failover
occurred
warn
A switchover occurred because of a hardware or
software failure or because the management
module reset button was pressed.
RMON_SYSTEM_MGMT_FAILOVER
269
Mgmt Module [1 or 2] - User initiated
switchover occurred
info
The user has initiated switchover using the
redundancy switchover
command so that the other
management module can become the active
management module.
RMON_SYSTEM_MGMT_SWITCHOVER
270
Mgmt Module [1 or 2] - Offline
(incompatible SW versions)
warn
The software version in the specified management
module is not compatible with the other module and
it has gone offline.
RMON_SYSTEM_MGMT_INCOMPAT_OS
271
Other management module is not in
standby, shutdown request ignored
warn
A shutdown request is ignored because the
standby module is not in standby mode. A
management module must be in active or standby
mode to be shut down. The module goes into a
“down” state which allows you to safely swap it
out.
RMON_SYSTEM_MGMT_HSBUTTONERR
272
Mgmt Module [1 or 2] Offline
(shutdown)
info
The specified management module is offline
because of a shutdown.
RMON_SYSTEM_MGMT_SHUTDOWN
273
Resetting Mgmt Module [1 or 2] <reason
for reset>
info
The indicated management module is being reset
for the reason displayed.
RMON_SYSTEM_MGMT_RESET_REASON
537
Syncing [primary |secondary] OS to
standby [started | completed]
info
This message is logged when the OS begins
synchronizing to the standby module. It displays the
status of the synchronization.
RMON_SYSTEM_OS_SYNC
538
Standby <boot image | default boot>
updated, rebooting standby
info
This message is logged when the standby’s
management module boot image is overwritten,
requiring a reboot.
RMON_SYSTEM_STANDBY_REBOOT
539
Initial active to standby sync <started |
completed>
info
Indicates the beginning or end of the initial
synchronization of the active management
module’s flash image to the standby management
module.
RMON_SYSTEM_INITIAL_SYNC
15-47
Содержание ProCurve 1600M
Страница 1: ...Management and Configuration Guide 8200zl ProCurve Switches K 12 XX www procurve com ...
Страница 2: ......
Страница 3: ...ProCurve Series 8200zl Switches September 2007 K 12 xx Management and Configuration Guide ...
Страница 68: ...Using the Menu Interface Where To Go From Here 3 16 ...
Страница 110: ...Using the ProCurve Web Browser Interface Status Reporting Features 5 26 ...
Страница 152: ...Switch Memory and Configuration Multiple Configuration Files 6 42 ...
Страница 192: ...Configuring IP Addressing IP Preserve Retaining VLAN 1 IP Addressing Across Configuration File Downloads 8 24 ...
Страница 220: ...Time Protocols SNTP Messages in the Event Log 9 28 ...
Страница 252: ...Port Status and Configuration Uni Directional Link Detection UDLD 10 32 ...
Страница 282: ...Power Over Ethernet PoE Operation PoE Operating Notes 11 30 ...
Страница 472: ...Redundancy Switch 8212zl Event Log Messages 15 48 ...
Страница 510: ...File Transfers Copying Diagnostic Data to a Remote Host USB Device PC or UNIX Workstation A 38 ...
Страница 584: ...Monitoring and Analyzing Switch Operation Locating a Device B 74 ...
Страница 652: ...Troubleshooting Restoring a Flash Image C 68 ...
Страница 660: ...MAC Address Management Viewing the MAC Addresses of Connected Devices D 8 ...
Страница 666: ...Monitoring Resources When Insufficient Resources Are Available E 6 ...
Страница 670: ...Daylight Savings Time on ProCurve Switches F 4 ...
Страница 688: ...18 Index ...
Страница 689: ......