Service Messages
158
Continuous Access Storage Appliance Installation and Maintenance Guide
Reading VSM states
lists the states that the VA Status Monitor (VSM) service gathers from the appliance’s
shared storage array.
Table 9: VSM states
Value
Name
Description
0
Ready
The subsystem is fully functional and ready to provide storage to meet
the host's needs. The subsystem has completed its power up sequence
prior to reaching this state.
1
Warning
The subsystem encountered an error requiring attention but the error
does not prevent access to data. Possible causes of the error include a
battery warning, loss of data availability, or loss of redundancy.
However, the error should not cause changes to the subsystem behavior
typically visible to the host. If the cause of the error is loss of data
availability, you can access data that is still present. You cannot access
data that is deemed unavailable.
2
Not Enough Drives
There are not enough drives to allow the system to function. The
minimum number of drives depends on a number of variables.
3
No Quorum
The Part field on the Subsystem Parameters mode page is clear. There
are not enough volume set member drives available to continue without
partitioning the volume set.
4
No Map
The subsystem lacks internal metadata that is critical to continued
operation. The data structures necessary to perform host data storage
commands are lost or have not been created. The possibility of
recovering lost data is remote (except when you remove and reinsert
drives). You may be able to recover data using drive pass through
commands, but successful recovery would be difficult at best.
5
Shutting Down
The subsystem receives a Shutdown command from the host and
remains in this state until:
■
All previously accepted commands complete.
■
All policies have been deactivated.
■
The subsystem metadata has been copied to disk(s).
After these tasks are completed, the subsystem enters the Shutdown
state.
6
Shutdown
The subsystem has completed policy deactivation and metadata backup
and is no longer performing host access commands. In this state, the
subsystem cannot perform data storage commands.
7
Starting Up
The subsystem is initializing, following a power on or reset. The
subsystem returns SCSI sense information that it is getting ready to
process the commands it is unable to complete while in this state.
8
No Code
The controller has lost microcode. The FLASH ROM has been erased
in preparation for a firmware update. This state persists until you update
the firmware and reset the subsystem.
9
Reserved
Reserved
Содержание Open View
Страница 22: ...Unpacking the Appliance 22 Continuous Access Storage Appliance Installation and Maintenance Guide ...
Страница 136: ...IP Mirroring 136 Continuous Access Storage Appliance Installation and Maintenance Guide ...
Страница 146: ...Appliance Components 146 Continuous Access Storage Appliance Installation and Maintenance Guide ...
Страница 184: ...Index 184 Continuous Access Storage Appliance Installation and Maintenance Guide ...