Local Boot direct attach FC 

NOTE:

 

Information pertains to boot requirements only. 

 

 

Superdome X Chassis 

One MSA 2040 SAN can support boot to all partitions 

• 

Use the Explicit Mapping feature of the array to assign boot disks 
 

One MSA 2040 array can support up to two (2) dual port array controllers 

• 

Each controller supports up to four (4) 8/16GB FC links 
 

Considerations for local boot 

• 

Minimum configuration: one controller 

 

One controller supports boot to all partitions but lacks controller redundancy or online f/w upgrading 

• 

Optimal configuration: two controllers 

 

Configure redundant boot paths to separate controllers 

 

Controller firmware may be independently upgraded without taking down the server partitions 
 

MSA 2040 

Enclosure 

with SDX 

Blades 

BladeSystem 
FC Switches 

Содержание Integrity Superdome X

Страница 1: ...QuickSpecs HPE Integrity Superdome X Overview Page 1 HPE Integrity Superdome X HPE Superdome X ...

Страница 2: ...QuickSpecs HPE Integrity Superdome X Overview Page 2 HPE BladeSystem Superdome Enclosure front HPE BladeSystem Superdome Enclosure back HPE BL920s Gen9 Server Blade ...

Страница 3: ...tiple nPARs supported for greater system reliability and licensing optimization Error Analysis Engine self heals by driving response to failures minimizing human error General The HPE BladeSystem Superdome Enclosure is the foundational building block for Superdome X Each compute enclosure supports 15 fans 12 power supplies associated power cords 2 Onboard Administrator OA modules 2 Global Partitio...

Страница 4: ...r commitment 24x7 coverage three year Care Pack Service Improve system availability and performance with personal attention from a locally assigned Account Support Manager while you increase stability and reduce unplanned downtime by connecting to Hewlett Packard Enterprise for automated problem detection This level of HPE Proactive Care Advanced combines rapid critical event management with the i...

Страница 5: ...ts that have reached their maximum supported lifetime and or the maximum usage limitations as set forth in the manufacturer s operating manual product QuickSpecs or the technical product data sheet will not be provided repaired or replaced as part of these services The defective media retention service feature option applies only to Disk or eligible SSD Flash Drives replaced by Hewlett Packard Ent...

Страница 6: ...30 v2 10c 2 2Ghz 20M 105W Intel Xeon Processor E7 8891 v2 10c 3 2Ghz 37 5M 155W Intel Xeon Processor E7 8893 v2 6c 3 4Ghz 37 5M 155W Chipset HPE sx3000 and XNC2 Upgradability and scalability Scalable from 2 socket configurations to 16 socket configurations Memory type for HPE BL920s Gen9 Server Blades HPE 64GB 4x16GB DDR4 2133 CAS 15 15 15 LRDIMM Memory Kit HPE 128GB 4x32GB DDR4 2133 CAS 15 15 15 ...

Страница 7: ...Interconnect Modules Partitioning Multiple 2 4 6 8 12 or one 16 socket electrically isolated HPE nPartitions HPE nPars supported NOTE BL920s Gen9 blades only NOTE BL920s Gen9 v4 blades only Form factor 18U Enclosure HPE 600 mm wide 42U Intelligent Series rack with standard rack door High availability standard server features 2N N N redundant power supplies N 1 fans or greater depending on the load...

Страница 8: ...mum Lifting Height Width stowed Capacity Weight GL 8 Standard Base GL 8 5 7 5 x 35 2 10 75 L Operating 2 0 75 W Outside 10 ft 5 in 2 ft 0 75 in 400 lbs 132 lbs HPE Superdome X systems are supported in the HPE 600 mm wide 42U Intelligent Series rack Other products may be placed in the same rack as Superdome X Placement of these other products must not result in moving the server enclosure All racks...

Страница 9: ...e as follows 1 Load the largest partitions first and in accordance with the supported nPAR configurations as documented herein 2 Odd even slot loading for BL920s blades in the same partition is required by nPAR sizing rules For instance a four blade partition must have blades loaded in slots 1 3 5 7 or 2 4 6 8 not slots 1 2 3 4 as in legacy Superdome 3 A BL920s blade must be in slot 1 of the enclo...

Страница 10: ...ay be ordered field racked but some disassembly is required The default assumption is that compute enclosures are loaded in the rack at the bottom It is recommended that 2U is left below the bottom of the compute enclosure in the 42U rack to provide PDU and cabling exit space The supported configuration is a single rack for a Superdome Enclosure at the bottom of the rack leaving space above for ot...

Страница 11: ... divided into three main configurations Single Phase only 16A 20A single phase cords that plug directly into wall sockets Connectors on back of the compute enclosure are IEC60320 C19 A total of 12 single phase power cords are necessary to power the 12 power supplies in the Superdome Enclosure power option 001 To limit the number of power cords exiting the rack decrease from 12 cords to 4 cords it ...

Страница 12: ...cessary to power the 12 power supplies in the Superdome Enclosure Below is a photo of the rear of a Superdome Enclosure with the three phase power interface modules installed All these options are offered for HPE Superdome X All PDUs supported in the HPE Superdome X are half depth such that two can fit in 1U one in the front and one in the back Many of the PDUs are offered in both 1U horizontally ...

Страница 13: ...13 Power Option Matrix Connections to the enclosure HPE Power Advisor The HPE power Advisor is a tool provided by Hewlett Packard Enterprise to assist in the estimation of power consumption at a system rack and multi rack level Available at https paonline56 itcs hpe com ...

Страница 14: ...z 60 MB 165W Intel Xeon Processor E7 8880 v4 22c 2 2 GHz 55 MB 150W Intel Xeon Processor E7 8855 v4 14c 2 1 GHz 35 MB 140W Intel Xeon Processor E7 8891 v4 10c 2 8 GHz 60 MB 165W Intel Xeon Processor E7 8893 v4 4c 3 2 GHz 60 MB 140W Intel Xeon Processor E7 v3 Family Processor of cores per processor Frequency Cache Power Intel Xeon Processor E7 8890 v3 18c 2 5 GHz 45 MB 165W Intel Xeon Processor E7 ...

Страница 15: ...nology on the memory controller and the DDR3 DIMMs The following DIMMs are supported on BL920s Gen9 blades 16GB DDR4 2133 CAS 15 15 15 LRDIMMs for BL920s Gen9 v3 32GB DDR4 2133 CAS 15 15 15 LRDIMMs for BL920s Gen9 v3 32GB DDR4 2400 CAS 17 LRDIMMs for BL920s Gen9 v4 64GB DDR4 2400 CAS 17 LRDIMMs for BL920s Gen9 v4 The following DIMMs are supported on BL920s Gen8 blades 16GB PC3 12800R DDR3 1600 Reg...

Страница 16: ...BL920s Gen8 Server Blade Recommended Configurations per BL920s Server Blade Total Memory per Blade GBytes Number of DIMMS Echelon A Echelon B Echelon C Echelon D Echelon E Echelon F 16GB DIMMs 32GB DIMMs 64GB DIMMs 256 16 16G 16G 512 Gen9 v3 32 16G 16G 16G 16G 512 16 32G 32G 768 Gen9 v3 48 16G 16G 16G 16G 16G 16G 1024 32 32G 32G 32G 32G 1024 Gen9 16 64G 64G 1536 48 32G 32G 32G 32G 32G 32G 2048 Gen...

Страница 17: ...uration Page 17 NOTE In order to route the I O from the FlexLOM and Mezzanine card slots on the individual server Blades the appropriate interconnect module must be installed in the appropriate I O Bay Interconnect HP 6127XLG Ethernet Blade Switch 787635 B21 ...

Страница 18: ...FlexFabric 10Gb 2 port 534FLB Adapter 700741 B21 HP FlexFabric 10Gb 2 port 534M Adapter 700748 B21 NOTE FlexLOM and Mezzanine I O cards mentioned are supported in HPE BL920s Server blades NOTE FlexFabric 534FLB 534M adapters not supported with Windows Server or SQL Server NOTE FlexFabric 20Gb 2 port 630 Adapters supported with BL920s Gen9 only Networking HP Ethernet 10Gb 2 port 560FLB Adapter 6556...

Страница 19: ... X Ordering and Configuration Page 19 Up to 8 partitions per enclosure Minimum partition size one blade Superdome X supports PXE boot for network disks Can use any of the supported Superdome X 20GbE and 10GbE FlexLOMs or mezzanine cards ...

Страница 20: ...support up to two 2 dual port array controllers Each controller supports up to four 4 8 16GB FC links Considerations for local boot Minimum configuration one controller One controller supports boot to all partitions but lacks controller redundancy or online f w upgrading Optimal configuration two controllers Configure redundant boot paths to separate controllers Controller firmware may be independ...

Страница 21: ...e updates of switch and array firmware No factory installation of operating environment Supported storage devices HPE Integrity Superdome X currently supports Fibre Channel data connectivity and boot support with the following HPE Storage devices HPE 3PAR StoreServ 20000 8000 7000 10000 Storage HPE MSA 2040 Storage HPE XP7 Storage HPE XP P9500 Storage HPE EVA P6000 Storage HPE EVAx400 Storage For ...

Страница 22: ... Web technology CLI for easy scripting and power user convenience Console for each nPartition simultaneously available from OA GUI or CLI Sharable enclosure DVD or remotely connected iLO virtual media can be used to attach a DVD ROM to nPartitions OA controlled power management features across the Superdome X HPE nPartitions Built in Error Analysis Engine constantly monitors all system hardware an...

Страница 23: ...1 HPE Superdome X 4 Wire No PDU 002 HPE Superdome X 5 Wire Intl No PDU 003 HPE Superdome X 4 Wire 3 Phase PDU 004 HPE Superdome X 5 Wire Intl 3 Phase PDU 005 HPE Superdome X 3 Wire Local SP PDU 006 HPE Superdome X Top Power 007 HPE Superdome X 3 Wire Japan SP PDU 010 Enclosure upgrade HPE Superdome X Crossbar Fabric 2 Module H7B49A NOTE The HPE Superdome X Crossbar Fabric 2 Module can be used to u...

Страница 24: ...rtition must be identical NOTE Min1 Max 1 iLO Advance LTU per blade HPE BL920s Gen9 v3 Server Blades HP Superdome X BL920s Gen9 8890 2 5GHz 36 core Server Blade A0R98A HP Superdome X BL920s Gen9 8880 2 3GHz 36 core Server Blade H7B40A HP Superdome X BL920s Gen9 8891 2 8GHz 20 core Server Blade A0S01A HP Superdome X BL920s Gen9 4850 2 2GHz 28 core Server Blade A0R99A HP Superdome X BL920s Gen9 8893...

Страница 25: ...istered CAS 13 Memory B9F09A NOTE Minimum 4 maximum 12 modules per blade Blade FlexLOM NOTE Minimum 1 maximum 2 per blade HP FlexFabric 20Gb 2 port 630FLB Adapter 700065 B21 HP FlexFabric 20Gb 2 port 650FLB Adapter 700763 B21 NOTE BL920s Gen9 only HP Ethernet 10Gb 2 port 560FLB Adapter 655639 B21 HP FlexFabric 10Gb 2 port 534FLB Adapter 700741 B21 NOTE BL920s Gen8 only NOTE FlexFabric 534FLB adapt...

Страница 26: ...ng Upgrade E LTU AT154AAE NOTE If 5 or more blades are ordered OR More than 1 partition is selected then AT152A is required NOTE AT150A or AT152A can be ordered with 4 blades or less with a single partition NOTE Min 1 Max 1 Superdome X partition LTU AT150A or AT152A required per enclosure ordered HPE iLO Advanced NOTE Min 1 Max 1 iLO Advanced license required per blade HPE iLO Advanced including 3...

Страница 27: ...309 16A or two 4 wire cords each NEMA L15 30P 30A 5 wire 12 26A per cord 4wire 23 3A per cord AC input power Single Phase 2N Dual Power input modules with 6 Input Receptacles each IEC C19 16 20A Maximum Input Current Single Phase 200V 13 8A per C19 cord Maximum Input Power total 9 250 VA at PF 98 or greater Cooling airflow 600 CFM min 1000 CFM 32 deg C avg 1900 CFM max Environmental Characteristic...

Страница 28: ...ease in system performance NOTE All temperature ratings shown are for sea level An altitude de rating of 1 C per 300 m above 900 m is applicable No direct sunlight allowed Upper operating limit is 3 048 m 10 000 ft Environmental Info Regulatory model numbers AT147A AT147B Superdome Enclosure RMN FCLSB 1001 AT068A BL920s Gen8 Server Blade RMN FCLSB BB31 Additional Power Data The maximum power figur...

Страница 29: ...ervice and Support HPE Care Pack and Warranty Information standard features ordering and configuration 28 Sep 2015 From Version 7 to 8 Changed Ordering and Configuration Overview and Standard Features sections were updated Added SKUs added C8S45A 648311 B21 648312 B21 700065 B21 702213 B21 648311 B21 648312 B21 A0R98A H7B40A A0S01A A0R99A H7B43A A0S02A H7B38A 700076 B21 702213 B21 17 Jul 2015 From...

Страница 30: ...ces are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein Hewlett Packard Enterprise makes no warranties for non Hewlett Packard Enterprise products Intel and Xeon are US registere...