NOTE:
To ensure good ventilation, install blank panels to the empty power supply slot.
Removing a power supply
1.
Wear an ESD wrist strap and make sure it makes good skin contact and is correctly grounded.
2.
Release the cable tie securing the power cable to the handle and remove the power cord from the
power supply.
3.
Push the latch on the power supply to the handle side with your forefinger and clasp your thumb
to the handle on the power supply, and pull the power supply part way out of the slot, as shown
.
4.
Supporting the power supply bottom with one hand, slowly pull the power supply out with the other
hand.
5.
Put away the removed power supply in an antistatic bag for future use.
Figure 18
Removing the power supply
(1) Push the latch to the handle side with the forefinger (2) Pull out the power supply
Connecting the power cord
IMPORTANT:
•
Use the power cord and the C15 connector supplied with the power supply.
•
Switch off the input circuit breaker before you connect the power cord to the switch.
Connecting an AC power cord to the switch
1.
Connect one end of the AC power cord to the AC-input power receptacle on the switch.
2.
Use cable tie to secure the power cord to the power supply handle, as shown in
3.
Connect the other end of the power cord to the AC power outlet.
16