Connecting the grounding cable to the chassis
CAUTION:
The primary grounding point and auxiliary grounding point are located on the left side panel. If you use
one of these grounding points, you must connect the grounding cable to the grounding point before you
mount the switch in the rack.
To connect the grounding cable to a chassis grounding point, for example, the primary grounding point:
1.
Unpack the grounding cable and grounding screws.
2.
Align the two-hole grounding lug at one end of the cable with the grounding holes of the
grounding point, insert the grounding screws into the holes, and tighten the screws with a
screwdriver to attach the grounding lug to the chassis, as shown in
.
Figure 6
Attaching the mounting brackets, chassis rails, and grounding cable to the chassis (power
supply side mounting position)
7