Viewing chassis information
Procedure
1. Click Chassis Information in the navigation tree.
2. (Optional) Click a power supply or smart storage energy pack listing to view additional details.
Chassis Information
•
Node Number—The server node number.
•
Chassis Name—The name of the chassis that contains the server node.
•
Chassis Serial Number—The serial number of the chassis that contains the server node.
•
Chassis Part Number— The part number of the chassis that contains the server node.
•
Chassis Power (Watts)—The power used by the chassis.
This value is updated every 10 seconds. To see the latest value, refresh the browser window.
•
Node Power (Watts)—The power used by the current node in the chassis.
This value does not include other nodes or devices in the chassis.
This value is updated every 15 seconds. To see the latest value, refresh the browser window.
Power Supplies list
The
Chassis Information page displays the following details about the power supplies in the chassis.
Some power supplies do not provide information for all the values on this page. If a power supply does not provide
information for a value,
N/A is displayed.
Bay
The chassis power supply bay number.
Present
Indicates whether a power supply is installed. The possible values are
OK and Absent.
Status
The status of the power supply. The displayed value includes a status icon (
OK, Degraded, Failed, or Other), and text
that provides more information. The possible values follow:
•
Unknown
•
Good, In Use
•
Good, Standby
•
General Failure
•
Over Voltage Failure
•
Over Current Failure
•
Over Temperature Failure
•
Input Voltage Lost
Using HPE iLO 5
99