background image

1500W Hot-plug Power Supply

Specification

Value

Input requirements

Rated input voltage

90 VAC to 264 VAC

Rated input frequency

47Hz to 63 Hz

Rated input current

15 A at 100 VAC

6.9 A at 240 VAC

Maximum rated input power

1394 W at 90 VAC

1636 W at 264 VAC

BTUs per hour

4757 at 90 VAC

5582 at 264 VAC

Power supply output

Rated steady-state power

1500 W at 200 VAC to 240 VAC

1400 W at 110 VAC to 120 VAC

1260 W for 100 VAC

Maximum peak power

1500 W at 200 VAC to 240 VAC

1400 W at 110 VAC to 120 VAC

1260 W for 100 VAC

-48VDC Hot Plug Power Supply

Specification

Value

Input requirements

Rated input voltage

-40 VDC to -72 VDC

-48 VDC nominal input

Rated input current

38 A at -48 VDC

25 A at -72 VDC

Rated input power (W)

1670 W at -48 VDC to -60 VDC

Table Continued

Specifications

107

Содержание Enterprise HPE Edgeline EL8000t

Страница 1: ... 2020 Edition 1 Abstract This document is for the person who installs administers and troubleshoots servers and storage systems Hewlett Packard Enterprise assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels ...

Страница 2: ...om Hewlett Packard Enterprise required for possession use or copying Consistent with FAR 12 211 and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial Items are licensed to the U S Government under vendor s standard commercial license Links to third party websites take you outside the Hewlett Packard Enterprise website Hewlett Packard Enterprise h...

Страница 3: ...it on a 23 inch rack column 13 Installing the four post rack mount kit 15 Associated hardware procedures 16 Powering down the system 16 Powering up the system 16 Removing the server blade from the chassis 16 Installing the server blade into the chassis 17 Set up HPE iLO on the HPE ProLiant e910t Server Blade 18 What is iLO 18 General security guidelines 18 Learn more about security settings for iL...

Страница 4: ... details 39 System status details 40 Connection to HPE status 41 Network details 41 Viewing health summary information 42 Redundancy status 42 Subsystem and device status 42 Subsystem and device status values 42 Viewing and managing firmware and software 43 Firmware updates 43 iLO firmware and software management 44 Special considerations for network module updates 45 Viewing installed firmware in...

Страница 5: ...ey RoHS material content declaration 103 Ukraine RoHS material content declaration 103 Federal Communications Commission notice for Class A equipment 103 Brazil certification notice 104 Japanese certification notice 104 Korean certification notice for class A equipment 104 Specifications 105 Environmental specifications 105 Mechanical specifications 106 Power supply specifications 106 1500W Hot pl...

Страница 6: ...uces costs by using open standards By reducing the need for proprietary edge systems the HPE EL8000t enables enhanced performance and versatility for data intensive real time digital services while providing a compact ruggedized design and modular blade and chassis options This guide includes setup and configuration information for the HPE Edgeline EL8000t Converged Edge chassis See https www hpe ...

Страница 7: ...orms to space airflow temperature and power requirements 3 Install one or more blades in the chassis if necessary 4 Determine the rack depth compatibility of the system and then install it in a rack Two post rack 5 Prepare to configure iLO on the server blades a Set up the dedicated management network connection b Plan for network addressing using dynamic or static IP addresses 6 Register your sys...

Страница 8: ...ement To allow for servicing and adequate airflow leave a minimum clearance of 20 cm 7 9 in around the system Power requirement Installation of this equipment must comply with local and regional electrical regulations governing the installation of information technology equipment by licensed electricians This equipment is designed to operate in installations covered by NFPA 70 1999 Edition Nationa...

Страница 9: ... 4a Management Chassis Controller module Left bay 1 4b Network module Right bay 5 HPE ProLiant e910t 2U server blade 6 Fan assembly 1 Management functionality is active for left bay only HPE Edgeline EL8000t Converged Edge chassis with HPE ProLiant e910t server blades installed The HPE EL8000t 2U chassis can accommodate up to two HPE ProLiant e910t server blades Component identification 9 ...

Страница 10: ...pply Solid Amber Power supply failed overvoltage undervoltage overtemperature overcurrent short circuit fan failed or input overvoltage protection Flashing Amber Power supply error Off No power present or standby power failed overvoltage undervoltage overtemperature overcurrent short circuit fan lock Component identification 10 ...

Страница 11: ...rack column to be installed on Rack mount option 2 2 1 1 3 Item Description 1 Front brackets 2 Rear brackets 3 Stop bracket Installing the two post rack mount kit on a 19 inch rack column Prerequisites Before you perform this procedure make sure that you have the following items available T 15 Torx screwdriver T 25 Torx screwdriver Procedure 1 Position the stop brackets on the rear brackets Place ...

Страница 12: ...2 Install the brackets on rack columns 3 Install the chassis on the rack Make sure that the stop brackets are slid into the rear of the chassis 2 1 2 Rack mount option 12 ...

Страница 13: ...orx screwdriver Procedure 1 Install the stop bracket on the rear brackets a Place the stop brackets at the last location on the rear brackets b Secure it with screws 2 Install rack adapter on the rear brackets a Align the arrows on the adapter with the number that corresponds to the width of the rack column on the rear bracket b Secure the rack adapter on the rear brackets Rack mount option 13 ...

Страница 14: ...3 Install the brackets on rack columns 4 Install the chassis on the rack Make sure that the stop brackets are slid into the rear of the chassis 2 1 2 Rack mount option 14 ...

Страница 15: ...re marked on the front of the adjustable rack mounting rails to indicate proper placement The shelves on the bottom of the left and right rail must be positioned towards the inside of the rack 2 To secure the standoff on the smaller section of the keyhole to lock the rail into place slide the rail towards the back of the rack column until you hear an audible click 3 Optional Install M5 shipping sc...

Страница 16: ...nstalled in the chassis for more than 4 seconds to force the system to power down This method forces the system to power down without properly exiting applications and the OS If an application stops responding you can use this method to force a shutdown Use the virtual power button in the iLO web interface hosted on the blade Powering up the system If the chassis is connected to a power source it ...

Страница 17: ...erver blade into the chassis Procedure 1 Align the server blade and install it in the chassis a Insert the server blade in the chassis b Close the latch on the server blade and secure it 1 2 Associated hardware procedures 17 ...

Страница 18: ...anagement network Do not connect iLO directly to the Internet IMPORTANT Change the iLO user account passwords immediately if iLO has been connected directly to the Internet Install an SSL certificate that is signed by a Certificate Authority CA You can perform this task on the SSL Certificate Information page Change the password for your user accounts including the default user account You can per...

Страница 19: ...eos Learn more about security settings for iLO 5 HPE developed a video to help teach you about security settings in iLO 5 To see the video click one of the following links HPE hosted video HPE YouTube video Read more about security in the HPE Gen10 Security Reference Guide at http www hpe com support gen10 security ref en Password guidelines Hewlett Packard Enterprise recommends that you follow th...

Страница 20: ...ore setting up an iLO management processor you must decide how to handle networking and security The following questions can help you set up iLO Procedure 1 How will iLO connect to the network 2 How will iLO acquire an IP address 3 What access security is required and what user accounts and privileges are needed 4 What tools will you use to configure iLO iLO network connection options You can conn...

Страница 21: ...DHCP servers are not available on the network a static IP address is used A static IP address can be configured by using the iLO 5 Configuration Utility If you plan to use a static IP address you must have the IP address before starting the iLO setup process iLO access security You can use the following methods to manage access to iLO Local accounts Up to 12 user accounts can be stored in iLO This...

Страница 22: ...com info redfish HPE Scripting Toolkit This toolkit is a server deployment product for IT experts that provides unattended automated installation for high volume server deployments For more information see the Scripting Toolkit user guide for Windows or Linux Scripting You can use scripting to set up multiple iLO management processors Scripts are XML files written for a scripting language called R...

Страница 23: ...nt Service AMS driver NOTE If you are installing the drivers in a secure boot environment see Secure Boot for Linux on HPE Servers for a complete set of instructions Information made available when the AMS driver is installed After installing the AMS driver the following information is available to Agentless Management and the iLO interface of the blade Information on the following tabs on the Sys...

Страница 24: ...Connect iLO to the network through a production network or a dedicated management network iLO uses standard Ethernet cabling which includes CAT 5 UTP with RJ 45 connectors Straight through cabling is necessary for a hardware link to a standard Ethernet hub or switch For more information about setting up your hardware see the server user guide iLO setup with the iLO 5 Configuration Utility Hewlett ...

Страница 25: ...To exit the System Utilities and resume the normal boot process click Exit and resume system boot Managing local user accounts with the iLO 5 Configuration Utility Adding user accounts iLO 5 Configuration Utility Procedure 1 Optional If you access the server remotely start an iLO remote console session 2 Restart or power on the server 3 Press F9 in the server POST screen The UEFI System Utilities ...

Страница 26: ...t Remove User 5 In the Action menu for the user you want to edit or remove select Edit The account properties are displayed 6 Update the Login Name 7 Update the Password a Move the cursor to the Password box and then press Enter The Enter your new password box opens b Type the password and then press Enter The Confirm your new password box opens c Type the password again to confirm and then press ...

Страница 27: ... hostname or IP address HTTPS HTTP exchanged over an SSL encrypted session is required for accessing the iLO web interface 2 Enter the default user credentials and then click Log In TIP After you log in to iLO for the first time Hewlett Packard Enterprise recommends changing the password for the default user account Managing the server power The Virtual Power Button section on the Server Power pag...

Страница 28: ...operating systems behave differently depending on a short press or long press Reset Forces the server to warm boot CPUs and I O resources are reset Using this option circumvents the graceful shutdown features of the operating system Cold Boot Immediately removes power from the server Processors memory and I O resources lose main power The server will restart after approximately 8 seconds Using thi...

Страница 29: ...gured Virtual Media port is not detected in a security audit that uses a port scanner to scan for security vulnerabilities Virtual Media Port The port that iLO uses to listen for incoming local Virtual Media connections The default value is 17988 SNMP Specifies whether iLO responds to external SNMP requests If you disable SNMP access iLO continues to operate and the information displayed in the iL...

Страница 30: ... and SSL communication When these settings are changed an iLO reset is required to activate the changes Prerequisites Configure iLO Settings privilege Procedure 1 Click Security in the navigation tree The Access Settings page is displayed 2 Update the service settings as needed When you disable a service setting iLO notifies you that the features that depend on the service setting will be unavaila...

Страница 31: ...face Specifies whether RIBCL commands can be used to communicate with iLO This setting is enabled by default RIBCL over HTTP HTTPS RIBCL through in band communication and RIBCL through the OA port do not work when this feature is disabled This option must be enabled when you register a server for Insight Remote Support central connect or Remote Support from HPE OneView The following message is dis...

Страница 32: ...isabled iLO responds to requests with an empty XML object When this option is enabled and the iLO health status is Degraded the iLO health status and a description of the issue are displayed on the login page The iLO health status is based on the combined results of the iLO diagnostic self tests Self test failures that could compromise security are not displayed in the description Serial Command L...

Страница 33: ... then press F5 Authentication Failure Logging Enables you to configure logging criteria for failed authentications The following settings are valid Enabled Every Failure A failed login log entry is recorded after every failed login attempt Enabled Every 2nd Failure A failed login log entry is recorded after every second failed login attempt Enabled Every 3rd Failure default A failed login log entr...

Страница 34: ...X characters represent the server serial number IMPORTANT Hewlett Packard Enterprise recommends changing the default password after you log in to iLO for the first time If you reset iLO to the factory default settings use the default iLO user credentials on the serial label pull tab to log in after the reset iLO licensing iLO standard features are included with every server to simplify server setu...

Страница 35: ...key NOTE If you have already signed up and applied a trial license to your server you cannot apply a trail license a second time The free trial license key can only be applied to your server once Test drive these today HPE iLO Advance Premium Security Edition HPE iLO Advanced HPE iLO Essentials iLO driver support iLO is an independent microprocessor running an embedded operating system The archite...

Страница 36: ...ant Server To gain access to iLO Advanced functionality you can unlock additional features with an add on license You can access HPE iLO from any location through a web browser or the iLO mobile application Troubleshooting information for supported events is available from Learn more links on the Integrated Management Log page With HPE iLO management you can simplify server setup proactively engag...

Страница 37: ...n to view the health status for iLO the server fans temperature sensors and other monitored subsystems For most health status values in the list you can click the status to view more information More information is not available for the Agentless Management Service AMS This icon varies depending on the summarized system health status Security icon This icon shows the iLO security status which is b...

Страница 38: ... attached to the server that contains the iLO management processor Use these values to access iLO remotely from a network client by using a web browser User name Administrator Password A random eight character string or a common default password The password type is defined at the factory and it depends on the SKU numbers included in the server order DNS name ILOXXXXXXXXXXXX where the X characters...

Страница 39: ...by using the ROM based system utilities during POST Serial Number Logical The system serial number that is presented to host applications This value is displayed only when set by other software This value might affect operating system and application licensing The Serial Number Logical value is set as part of the logical server profile that is assigned to the system If the logical server profile i...

Страница 40: ... Degraded To navigate to the Diagnostics page click the iLO Health link iLO Security The iLO security status which is based on the combined results from the Security Dashboard page The possible values are OK Ignored and Risk To navigate to the Security Dashboard page click the iLO Security link Server Power The server power state ON or OFF To access the virtual power button features click the Serv...

Страница 41: ... The server is registered Registration incomplete The server is registered for Insight Online direct connect remote support but step 2 of the registration process is incomplete Not registered The server is not registered Unable to retrieve the HPE Remote Support information The registration status could not be determined Remote Support Registration Error A remote support connection error occurred ...

Страница 42: ... column heading 3 Optional To navigate to a related page for supported subsystem and device types click the name of a value in the Subsystems and Devices list Some subsystem and device types such as the Agentless Management Service do not have a related page Redundancy status Redundancy status is displayed for the following Fan Redundancy Power Subsystem and device status Summarized status informa...

Страница 43: ...ity updates You can update firmware by using an online or offline firmware update method Online firmware update When you use an online method to update firmware you can perform the update without shutting down the server operating system Online firmware updates can be performed in band or out of band In band Firmware is sent to iLO from the server host operating system The iLO drivers are required...

Страница 44: ...t Management Processors You do not need to use directory integration to take advantage of the HPLOMIG firmware update capabilities HPLOMIG can be used to discover multiple iLO processors and update their firmware in one step SMASH CLP Access SMASH CLP through the SSH port and use standard commands to view firmware information and update firmware LOCFG PL Use a Perl sample to send RIBCL scripts to ...

Страница 45: ...nt update performed from an installed operating system are automatically applied to the default network module only No firmware updates can be applied to the right side module The right side module only provides 1G internal port connections and iLO connectivity to the e910t server blades in the chassis and will not require firmware updates Viewing installed firmware information Procedure 1 Click F...

Страница 46: ... location of the component that uses the listed firmware Replacing the active system ROM with the redundant system ROM Prerequisites Host BIOS privilege The server supports redundant system ROM Procedure 1 Click Firmware OS Software in the navigation tree 2 On the Installed Firmware page click next to the Redundant System ROM details iLO prompts you to confirm the request 3 Click OK The change wil...

Страница 47: ...cify the location of the firmware component In the Remote file URL box enter the URL for a firmware component on an accessible web server 6 Optional To save a copy of the component to the iLO Repository select the Also store in iLO Repository check box 7 Optional If a version of the component you selected in step 5 exists in the System Recovery Set select the Update Recovery Set check box to repla...

Страница 48: ...ware update types are supported depending on the server platform Some common examples follow iLO System ROM BIOS Chassis Power Management Controller System Programmable Logic Device CPLD Backplane Innovation Engine IE Server Platform Services SPS Language Packs Some firmware types are delivered as a combined update For example A SAS Programmable Logic Device update is often combined with a SAS con...

Страница 49: ...component 3 Extract the BIN file For Windows components Double click the downloaded file and then click the Extract button Select a location for the extracted files and then click OK For Linux components Depending on the file format enter one of the following commands firmware_file_name scexe unpack tmp rpm2cpio firmware_file_name rpm cpio id The name of the iLO firmware image file is similar to i...

Страница 50: ...the file extension bin Language Pack files use the extension lpk Viewing software information Prerequisites To display a complete set of data on this page AMS must be installed Procedure 1 Click Firmware OS Software in the navigation tree and then click the Software tab 2 Optional To update the software information data click The information on this page is cached in the browser and iLO displays t...

Страница 51: ...intenance window is a configured time period that applies to an installation task You can create a maintenance window On the Maintenance Windows tab When you add a task to the installation queue Adding a maintenance window Prerequisites Configure iLO Settings privilege Procedure 1 Click Firmware OS Software in the navigation tree and then click Maintenance Windows 2 Click iLO prompts you to enter ...

Страница 52: ...maintenance window name in the Name box 4 Update the description in the Description box 5 Update the maintenance window start and end times in the From and To boxes a Click in the From box A calendar is displayed b Select a start date and time and then click Done c Click in the To box A calendar is displayed d Select the end date and time and then click Done Enter the date and time based on the lo...

Страница 53: ...dows are canceled Viewing maintenance windows Procedure 1 Click Firmware OS Software in the navigation tree and then click Maintenance Windows 2 Optional To sort by a table column click the column heading To change the sort order to ascending or descending click the column heading again or click the arrow icon next to the column heading 3 Optional Click an individual maintenance window to view det...

Страница 54: ...ivilege is required for making an optional update to the System Recovery Set after you upload a file to the iLO Repository If you want to use the Update Recovery Set feature a System Recovery Set must exist and contain the component you want to update Procedure 1 Click Firmware OS Software in the navigation tree and then click Upload to iLO Repository If the browser window is a small size and the ...

Страница 55: ... iLO Repository and Installation Queue pages If a previously queued task is waiting to start or finish a new task might be delayed indefinitely For example if a queued component is installable by the UEFI BIOS a server restart is required before installation can start If the server is not restarted the tasks that follow in the queue are delayed indefinitely Prerequisites Configure iLO Settings pri...

Страница 56: ...dure 1 Click in the From box A calendar is displayed 2 Select a start date and time and then click Done The selected date and time are displayed in the From box 3 Click in the To box A calendar is displayed 4 Select an end date and time and then click Done This value sets the expiration date and time for the tasks in the install set The selected date and time are displayed in the To box Removing a...

Страница 57: ...the sort order to ascending or descending click the column heading again or click the arrow icon next to the column heading 3 Optional To view detailed component information click an individual component iLO Repository storage details The Summary section of the iLO Repository page displays the following details about the iLO Repository storage use Capacity Total iLO Repository storage capacity In ...

Страница 58: ...the installation queue Prerequisites The Configure iLO Settings privilege is required for adding tasks to the installation queue The Recovery Set privilege is required for making an optional update to the System Recovery Set after a queued update is completed successfully If you want to use the Update Recovery Set feature a System Recovery Set must exist and contain the component you want to updat...

Страница 59: ...ed component Selecting this option replaces the component even if the version in the System Recovery Set is newer This option is not displayed if A command is selected There is no System Recovery Set Your user account is not assigned the required privilege 8 If the server has a TPM or TM suspend or back up any software that stores information on the TPM or TM then select the Confirm TPM override c...

Страница 60: ... The selected date and time are displayed in the To box How tasks in the installation queue are processed When you add a task to the installation queue It is added to the end of the queue If you added a command the task is initiated after existing queued tasks finish If you added a component the task is initiated after Existing queued tasks finish The software that initiates installation for the s...

Страница 61: ...onent or Command box If the original task is a component update you can select only another component If the original task is a command you can select only another command 5 If the Wait command is selected enter or update the wait time in the Wait time seconds box Valid values are from 1 to 3600 seconds 6 Optional If you want to specify or edit the installation schedule select or clear the Set sch...

Страница 62: ...sing access to your data 9 Click OK iLO notifies you that the task was updated If the task would expire before the start time of a task that precedes it in the queue iLO notifies you that it cannot save the task The installation queue is a first in first out list of tasks and you cannot create a task that will expire before an existing task will run If you selected the Update Recovery Set check bo...

Страница 63: ...ask will run when the software that initiates updates for the component type detects the installation request In progress The task is being processed Complete The task completed successfully Canceled The task is associated with a canceled or expired maintenance window Expired The task is expired Subsequent tasks will not run until this task is removed from the queue Exception The task could not co...

Страница 64: ...s configured to run during a maintenance window Start time The task start date and time UTC If a time window is specified the start time is listed If a maintenance window is selected the maintenance window start time is listed If a start time is not specified and the task state is Complete Expired or Exception the value N A is displayed If a start time is not specified and the task state is InProg...

Страница 65: ...tons Momentary Press Press and Hold Reset Cold Boot The Press and Hold Reset and Cold Boot options are not available when the server is powered off 3 When prompted to confirm the request click OK Virtual power button options Momentary Press The same as pressing the physical power button If the server is powered off a momentary press will turn on the server power Some operating systems might be con...

Страница 66: ...river versions and settings The Active Health System does not parse or change OS data from third party error event log activities for example content created or passed through the OS Active Health System Log The data collected by the Active Health System is stored in the Active Health System Log The data is logged securely isolated from the operating system and separate from customer data Host res...

Страница 67: ...h the Hewlett Packard Enterprise privacy statement This information is not written to the log data stored on the server 4 Click Download 5 Save the file 6 If you have an open support case you can email the log file to gsd_csc_case_mngmt hpe com Use the following convention for the email subject CASE case number Files that are larger than 25 MB must be compressed and uploaded to an FTP site If need...

Страница 68: ...ded contact Hewlett Packard Enterprise for FTP site information 7 Optional Upload the file to the Active Health System Viewer For more information see https www hpe com servers ahsv Clearing the Active Health System Log If the log file is corrupted or if you want to clear and restart logging clear the Active Health System Log Prerequisites Configure iLO Settings privilege Procedure 1 Click Informa...

Страница 69: ...ntegrated remote console Applet For Windows or Linux clients with the Java plug in On Linux systems with OpenJDK you must use the Applet option with a browser that supports a Java plug in On blade servers the integrated remote console is always enabled Other remote console access options The following remote console options are available from outside of the iLO web interface Standalone remote cons...

Страница 70: ... based remote console The configured remote console port is not detected in a security audit that uses a port scanner to scan for security vulnerabilities To view this setting on the Access Settings page click the Remote Console Status link Remote Console Port The configured remote console port The default value is 17990 To view this setting on the Access Settings page click the Remote Console Por...

Страница 71: ...or Microsoft Internet Explorer and Microsoft Edge users only You connected to the iLO web interface by using a hostname or an IPv4 address The HTML5 IRC is not supported with Microsoft Internet Explorer or Microsoft Edge over an IPv6 connection The Microsoft WebSocket implementation requires a nonstandard IPv6 literal address Procedure 1 Click Information in the navigation tree and then click the ...

Страница 72: ...re The Maximize icon maximizes the remote console window within the browser window The Restore icon resets the window to its previous size Switch to full screen This icon enables you to change from windowed mode to full screen mode Close Remote Console This icon disconnects the remote console session Docked mode When you use docked mode the remote console is displayed in a navigation pane thumbnai...

Страница 73: ...he default position of the menu is the top left Click and drag to move the menu to a different position If you change the menu position the change persists for the current remote console session Pin icon This icon enables you to pin or unpin the toolbar at the top of the screen This setting persists for the current remote console session Menu This icon enables you to do the following Access the iL...

Страница 74: ...ormation about the available license types and the features they support see the licensing documentation at the following website https www hpe com support ilo docs The Remote Console feature is enabled on the Access Settings page A supported version of the Microsoft NET Framework is installed Pop up blockers are disabled In some cases you can bypass the pop up blocker by Ctrl clicking the NET Con...

Страница 75: ...isplayed if Internet Explorer is configured to hide the user agent string The Microsoft Edge browser does not display information about the installed NET Framework version Microsoft ClickOnce The NET IRC is launched using Microsoft ClickOnce which is part of the NET Framework ClickOnce requires that any application installed from an SSL connection must be from a trusted source If a browser is not ...

Страница 76: ...he Overview page Use this procedure to start the Java IRC in environments with Windows or Linux and the Oracle JRE The version of the Java IRC that supports the Oracle JRE is a Java Web Start application Prerequisites Remote Console privilege A license that supports this feature is installed For information about the available license types and the features they support see the licensing documenta...

Страница 77: ...e console launch button The Java plug in is installed in the client browser Procedure 1 Click Remote Console Media in the navigation tree The Launch tab displays the remote console launch options 2 Click the Applet button 3 If a Security Warning dialog box or a confirmation dialog box appears follow the onscreen instructions to continue 4 If you are prompted to confirm that you want to run the app...

Страница 78: ...sion leader clicks Yes you are granted access to the session with access to the keyboard and mouse Shared remote console NET IRC only The shared remote console feature allows multiple users to connect to the same remote console session This feature can be used for activities such as training and troubleshooting The first user to initiate a remote console session connects to the server normally and...

Страница 79: ...isplayed in the center of the status bar Screen Capture You can click the camera icon in the HTML5 IRC to create a screen capture of the activity displayed in the console window Encryption The status and encryption type of the connection between the remote console and iLO Health status The server health indicator This value summarizes the condition of the monitored subsystems including overall sta...

Страница 80: ...trl Alt Del action click the Virtual Keyboard icon and then click the CTRL ALT DEL keyboard shortcut To enable or disable the Caps Lock or Num Lock setting do one of the following Press the NumLock or CapsLock key on your client keyboard Click the Virtual Keyboard icon and then click the CAPS or NUM keyboard shortcut Sending a keyboard action with the NET IRC or Java IRC Prerequisites Remote Conso...

Страница 81: ...he Launch tab displays the remote console launch options 2 Start a remote console 3 On your client keyboard press the key combination for a configured remote console hot key Changing the keyboard layout in the HTML5 IRC Prerequisites Remote Console privilege A license that supports this feature is installed For information about the available license types and the features they support see the lic...

Страница 82: ...Click the Menu icon and then select an option from the Power menu The Press and Hold Reset and Cold Boot options are not available when the server is powered off iLO prompts you to confirm the request 4 Click OK Using the remote console virtual power switch with the NET IRC or Java IRC Prerequisites Remote Console privilege Virtual Power and Reset privilege A license that supports this feature is ...

Страница 83: ...n features of the operating system Cold Boot Immediately removes power from the server Processors memory and I O resources lose main power The server will restart after approximately 8 seconds Using this option circumvents the graceful shutdown features of the operating system Virtual media IRC features The integrated remote console IRC allows you to perform the following tasks Connect and disconn...

Страница 84: ...ct Floppy Local img file for an IMG file or select CD DVD Local iso file for an ISO file The remote console prompts you to select a disk image 4 Enter the path or file name of the image file in the File name text box You can also browse to the image file location and then click Open The virtual drive activity LED will show virtual drive activity Using a local IMG or ISO with the NET IRC or Java IR...

Страница 85: ...ll install an operating system on an NVMe drive the Boot Mode is set to Unified Extensible Firmware Interface UEFI Procedure 1 Download and extract the required driver You can obtain drivers from the SPP or download them from the following website https www hpe com support hpesc 2 Copy the driver to a USB key or a folder on the client where you will access the remote console 3 Start the remote con...

Страница 86: ...s The Remote Console feature is enabled on the Access Settings page The Virtual Media feature is enabled on the Access Settings page The image file you want to use is on a web server on the same network as iLO Procedure 1 Click Remote Console Media in the navigation tree The Launch tab displays the remote console launch options 2 Start the HTML5 IRC 3 Click the Virtual Media icon and select Floppy...

Страница 87: ...Console feature is enabled on the Access Settings page The Virtual Media feature is enabled on the Access Settings page Procedure 1 Click Remote Console Media in the navigation tree The Launch tab displays the remote console launch options 2 Start the NET IRC 3 Select Virtual Drives Folder 4 In the Browse For Folder window select the folder you want to use and then click OK The virtual folder is m...

Страница 88: ...onsole Media in the navigation tree The Launch tab displays the remote console launch options 2 Start the Java IRC 3 Select Virtual Drives Create Disk Image The Create Media Image dialog box opens 4 Verify that the Disk Image button is displayed If the button label is Image Disk click the button to change it to Disk Image 5 Do one of the following If you will use a file select Media File and then ...

Страница 89: ... video streams of events such as startup ASR events and sensed operating system faults iLO automatically captures the server startup and server prefailure sequences You can manually start and stop the recording of console video The server startup and server prefailure sequences are not captured automatically during firmware updates or while the remote console is in use Server startup and server pr...

Страница 90: ...e remote console launch options 2 Start the NET IRC 3 Press the Play button The Playback Source dialog box opens 4 Select Server Startup or Server Prefailure 5 Click Start Saving server startup and server prefailure video files Prerequisites Remote Console privilege A license that supports this feature is installed For information about the available license types and the features they support see...

Страница 91: ... Record button The Save Video dialog box opens 4 Enter a file name and save location and then click Save 5 When you are finished recording press the Record button again to stop recording Viewing saved video files with the remote console Prerequisites Remote Console privilege The Remote Console feature is enabled on the Access Settings page A license that supports this feature is installed For info...

Страница 92: ...tion tree The Launch tab displays the remote console launch options 2 Start the HTML5 remote console 3 Click the camera icon in the status bar A screen capture opens in a new browser tab Capturing the NET IRC screen Use the remote console screen capture feature when you want to save a screen capture of the server activity For example you might want to capture a POST code displayed on the remote co...

Страница 93: ...send Alt F4 to the remote server Example 2 If you want to create a hot key to send the international AltGR key to the remote server use R_ALT in the key list NOTE If will you do a lot of typing in remote console sessions you might want to avoid assigning hot keys that use Ctrl X and Ctrl V shortcuts These shortcuts are normally assigned to the cut and paste features Creating remote console hot key...

Страница 94: ...US d y NUM MINUS e z Resetting hot keys Resetting the hot keys clears all current hot key assignments Prerequisites Configure iLO Settings privilege Procedure 1 Click Remote Console Media in the navigation tree and then click the Hot Keys tab 2 Click Reset Hot Keys iLO prompts you to confirm the request 3 When prompted to confirm the request click Yes reset hot keys Using HPE iLO 5 94 ...

Страница 95: ...when you close the window Prerequisites Configure iLO Settings privilege Procedure 1 Click Remote Console Media in the navigation tree and then click the Security tab 2 Select from the following Remote Console Computer Lock settings Windows Custom and Disabled 3 If you selected Custom select a computer lock key sequence 4 To save the changes click Apply Remote console computer lock options Windows...

Страница 96: ...include major host system events that appear in the IML For example if a fan failure occurs an event is recorded in the IML and an email message with the details is sent to the configured email addresses Some email service providers establish filters and rules to block problem emails such as spam commercial content and unwanted volume These tools might block the receipt of messages generated by iL...

Страница 97: ...abled The test AlertMail is initiated 9 Optional If you sent a test message check the iLO event log to confirm that it was sent successfully AlertMail options Recipient Email Address One or more destination email addresses to receive iLO email alerts You can enter multiple email addresses separated by a semicolon Enter the addresses in standard email address format You can enter up to 260 characte...

Страница 98: ...password for an email account on the SMTP server SMTP Username The username up to 63 characters for an account on the configured SMTP Server This value is required if Enable SMTP Authentication is enabled To clear this value disable the Enable SMTP Authentication option delete the text in this box and then click Apply Change SMTP Password Click this check box to enter or update and confirm the pas...

Страница 99: ...value does not include other nodes or devices in the chassis This value is updated every 15 seconds To see the latest value refresh the browser window Power Supplies list The Chassis Information page displays the following details about the power supplies in the chassis Some power supplies do not provide information for all the values on this page If a power supply does not provide information for...

Страница 100: ... the Power Supplies section the following information is displayed Present Indicates whether a power supply is installed The possible values are OK and Absent Status The status of the power supply The displayed value includes a status icon OK Degraded Failed or Other and text that provides more information The possible values follow Unknown Good In Use Good Standby General Failure Over Voltage Fai...

Страница 101: ...cement to the iPDU technology If the chassis power supply is connected to an iPDU additional information is displayed in the Intelligent Power Distribution Units section Hotplug Whether the power supply bay supports swapping the power supply when the chassis is powered on If the value is Yes and the power supplies are redundant the power supply can be removed or replaced when the chassis is powere...

Страница 102: ...l regulatory information Hewlett Packard Enterprise is committed to providing our customers with information about the chemical substances in our products as needed to comply with legal requirements such as REACH Regulation EC No 1907 2006 of the European Parliament and the Council A chemical information report for this product can be found at https www hpe com info reach For Hewlett Packard Enter...

Страница 103: ...key RoHS material content declaration Türkiye Cumhuriyeti AEEE Yönetmeliğine Uygundur Ukraine RoHS material content declaration Federal Communications Commission notice for Class A equipment This device complies with part 15 of the FCC Rules Operation is subject to the following conditions This device may not cause harmful interference This device must accept any interference received including in...

Страница 104: ...s or modifications not expressly approved by the party responsible for compliance could void the authority of the user to operate the equipment Brazil certification notice WARNING Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente autorizados Japanese certification notice IMPORTANT 5 2GHz 帯及び 5 3GHz 帯の利用は 総務省に登録済の 5 ...

Страница 105: ...eration over 3 048 m 10 000 ft 2 Fan failure might reduce performance Table 2 ASHRAE Class A4 specifications Specification Value Temperature range1 Operating 0 C to 45 C 32 F to 113 F Nonoperating 10 C to 60 C 22 F to 140 F Relative humidity noncondensing Operating 8 to 90 at 28 C 82 4 F maximum wet bulb temperature Non Operating 5 to 95 at 38 7 C 101 7 F maximum wet bulb temperature 1 All tempera...

Страница 106: ...f change is 20 C per hour 36 F per hour No restrictions on product configurations except for rotating hard drives PCI cards must be rated for continuous operation with 60 C cooling air Solid state drives must be rated for continuous operation with 65 C cooling air Not rated for operation over 3 030 m 10 000 ft Mechanical specifications Specification Value Height 8 73 cm 3 44 in Depth 42 95 cm 16 9...

Страница 107: ...82 at 264 VAC Power supply output Rated steady state power 1500 W at 200 VAC to 240 VAC 1400 W at 110 VAC to 120 VAC 1260 W for 100 VAC Maximum peak power 1500 W at 200 VAC to 240 VAC 1400 W at 110 VAC to 120 VAC 1260 W for 100 VAC 48VDC Hot Plug Power Supply Specification Value Input requirements Rated input voltage 40 VDC to 72 VDC 48 VDC nominal input Rated input current 38 A at 48 VDC 25 A at ...

Страница 108: ...designed to permit the connection of the earthed conductor of the DC supply circuit to the earthing conductor at the equipment If this connection is made all the following must be met This equipment must be connected directly to the DC supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode conductor is...

Страница 109: ...info EIL Hewlett Packard Enterprise Edgeline Documentation www hpe com info edgeline docs Hewlett Packard Enterprise Edgeline Information www hpe com info edgeline Hewlett Packard Enterprise OT Link and Workload Orchestrator Information https www hpe com info OTLink WO FAQ Websites 109 ...

Страница 110: ... updates Some software products provide a mechanism for accessing software updates through the product interface Review your product documentation to identify the recommended software update method To download product updates Hewlett Packard Enterprise Support Center https www hpe com support hpesc Hewlett Packard Enterprise Support Center Software downloads https www hpe com support downloads My ...

Страница 111: ...HPE Proactive Care service Supported products list https www hpe com services proactivecaresupportedproducts HPE Proactive Care advanced service Supported products list https www hpe com services proactivecareadvancedsupportedproducts Proactive Care customer information Proactive Care central https www hpe com services proactivecarecentral Proactive Care service activation https www hpe com servic...

Страница 112: ...e com info ecodata For Hewlett Packard Enterprise environmental information including company programs product recycling and energy efficiency see https www hpe com info environment Documentation feedback Hewlett Packard Enterprise is committed to providing documentation that meets your needs To help us improve the documentation send any errors suggestions or comments to Documentation Feedback doc...

Отзывы: