![HP DL760 - ProLiant - 1 GB RAM Скачать руководство пользователя страница 157](http://html.mh-extra.com/html/hp/dl760-proliant-1-gb-ram/dl760-proliant-1-gb-ram_user-manual_159800157.webp)
Installing Hardware Options, Hot-Pluggable
Table 5-5: I/O Expansion Slots
Slot Description
Slots 1 and 2
Bus 19—Supports PCI-X expansion boards at 100 MHz and 66 MHz or PCI
expansion boards at 66 MHz and 33 MHz; it is keyed for 3.3v signaling.
Slots 3 and 4
Bus 13—Supports PCI-X expansion boards at 100 MHz and 66 MHz or PCI
expansion boards at 66 MHz and 33 MHz; it is keyed for 3.3v signaling.
Slots 5 and 6
Bus 11—Supports PCI-X expansion boards at 100 MHz and 66 MHz or PCI
expansion boards at 66 MHz and 33 MHz; it is keyed for 3.3v signaling.
Slots 7 and 8
Bus 7—Supports PCI-X expansion boards at 100 MHz and 66 MHz or PCI
expansion boards at 66 MHz and 33 MHz; it is keyed for 3.3v signaling.
Slot 9
Bus 0—Supports PCI expansion boards at 33 MHz; it is keyed for 5v signaling.
Slots 10 and 11
Bus 3—Supports PCI-X expansion boards at 100 MHz and 66 MHz or PCI
expansion boards at 66 MHz and 33 MHz; it is keyed for 3.3v signaling.
Note:
The operating system detects PCI devices in the following slot order: 9-10-11-7-8-5-6-3-4-1-
2.
NOTE:
It is recommended that you install the optional RILOE II board into slot 9.
NOTE:
Each PCI-X bus will automatically configure to run in the most advanced mode
(PCI-X or PCI) and the highest frequency supported by all expansion boards installed in the
slots on the bus.
NOTE:
The ProLiant DL760 G2 server ships with a NIC preinstalled in slot 11.
5-42
HP ProLiant DL760 Generation 2 Server User Guide
HP CONFIDENTIAL
Writer: Bryce Miller File Name: f-ch5 Installing Options-Hot Pluggable.doc
Codename: Comet Part Number: 201264-001 Last Saved On: 6/17/03 9:47 AM