Troubleshooting 84
2.
If the line you are accessing requires error control to be turned off, do so using the AT command
AT&Q6%C0
.
3.
Be sure no line interference exists. Retry the connection by dialing the number several times. If
conditions remain poor, contact the telephone company to have the line tested.
4.
Be sure the modem is current and compliant with CCITT and Bell standards. Replace with a
supported modem if needed.
You are unable to connect to an online subscription service
Action
:
1.
If the line you are accessing requires error control to be turned off, do so using the AT command
AT&Q6%C0
.
2.
If the ISP you are accessing requires access at a decreased baud rate, reconfigure the
communications software to correct the connection baud rate to match the ISP.
3.
If this does not work, force a slower baud rate (14400 baud) with the AT command
AT&Q6N0S37=11
.
You are unable to connect at 56 Kbps
Action
:
1.
Find out the maximum baud rate at which the ISP connects, and change the settings to reflect this.
Reattempt to connect at a lower baud rate.
2.
Be sure no line interference exists. Retry the connection by dialing the number several times. If
conditions remain poor, contact the telephone company to have the line tested.
Network controller problems
Network controller is installed but not working
Action
:
1.
Check the network controller LEDs to see if any statuses indicate the source of the problem. For LED
information, refer to the network controller documentation.
2.
Be sure no loose connections (on page
54
) exist.
3.
Be sure the network cable is working by replacing it with a known functional cable.
4.
Be sure a software problem has not caused failure. Refer to the operating system documentation for
guidelines on adding or replacing PCI Hot Plug devices, if applicable.
5.
Be sure the server and operating system support the controller. Refer to the server and operating
system documentation.
6.
Be sure the controller is enabled in the BIOS Setup Utility.
7.
Check the PCI Hot Plug power LED to be sure the PCI slot is receiving power, if applicable.
8.
Be sure the server ROM is up to date.
9.
Be sure the controller drivers are up to date.
10.
Be sure a valid IP address is assigned to the controller and that the configuration settings are correct.
11.
Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
51
) and replace failed components as
indicated.
Содержание DL100 - ProLiant G2 320GB File Print Appliance
Страница 46: ...Cabling 46 BBWC battery cabling to an optional controller Power supply 500 W cabling ...
Страница 47: ...Cabling 47 SATA cabling SATA cabling to the SGPIO connector and the 12C cable connector ...
Страница 48: ...Cabling 48 SAS cabling to the SGPIO connector and the 12C cable connector Internal USB cabling ...
Страница 49: ...Cabling 49 Fan cabling ...
Страница 107: ...Technical support 107 ...
Страница 108: ...Technical support 108 ...
Страница 112: ...Acronyms and abbreviations 112 UID unit identification USB universal serial bus ...