![HP dat72 5242 Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/hp/dat72-5242/dat72-5242_user-manual_165450062.webp)
Section 4: SCSI Bridge Electronics
2.5.2.1 Numeric Entry Method
Enables you to change a setting by entering a decimal or hexadecimal number digit by
digit. The LCD shows the instruction
PRESS to Incremnt.
On the second line, the digit
to the right is highlighted and currently alterable. To increment the digit, press the mode
switch. Continue this process through all the sequentially highlighted digits. When the
highlight proceeds past the rightmost digit, the display shows
PRESS if Done
, allowing
you to confirm the change. If the numerical value requires additional editing, do not press
the mode switch. Wait until the highlight restarts at the leftmost digit and then continue
editing the setting.
SCSI ID:
[00]
PRESS to
Alter
SCSI ID:
[01]
PRESS if
Done
SCSI ID:
[01]
PRESS to
Incremnt
Figure 52 Numeric entry example
2.5.2.2 Pick Entry Method
Allows you to select from a predefined list of items. When
PRESS to Scroll
displays on
the LCD, you can view the list of items by pressing the mode switch. When the switch is
inactive for four seconds, the instruction
PRESS if Done
appears to allow you to confirm
the setting. If you want the setting, wait until the
PRESS to Scroll
instruction appears on
the LCD and then continue editing.
BaudRate
9600 bps
PRESS to
Scroll
BaudRate
1200 bps
PRESS to
Scroll
BaudRate
9600 bps
PRESS to
Alter
BaudRate
19K2 bps
PRESS if
Done
BaudRate
2400 bps
PRESS to
Scroll
Figure 53
Pick entry example
HP StorageWorks DAT 72 (Models 5242 and 5242-ACL) User's Guide
55 HP Part Number 528296-03 July 2005