Section 1: General Information
Use the SCF
START TAPE
command to start a tape device after the 5242 or 5242-ACL
tape drive has been installed. The
START
command makes a stopped tape drive accessible
to user processes. When the
START
command finishes successfully, the tape drive is in the
STARTED
state. For more on the
START
command, see the
SCF Reference Manual for
the Storage Subsystem
. For example:
->START $TAPE0
3.2.4.2 Testing a Tape Device
Use the SCF
STATUS TAPE, DETAIL
command to produce a report that shows
information such as processor numbers for the tape process, logical device number of the
tape device, and current state of the tape device. For example:
->STATUS TAPE $TAPE0, DETAIL
STORAGE – Detailed Status TAPE $TAPE0
Tape Process Information:
LDev
State
SubState
Primary
Backup
DeviceStatus
PID
PID
68
STARTED
0,291
1,273
ONLINE,BOT
Current Settings:
ACL ..............NOT INSTALLED/UNK
BufferLevel .......RECORD
CheckSumMode .....NORMAL I/O
*Compression ......OFF
Density ..........2.4-4.8 KB/mm
Media Type ........Not applicable
Opens ............0
Product ...........5140/5142
RecSize ..........2048
Short Write Mode ..ALLOWED, PADDED
Subtype ..........11
Tape Mode .........STREAM
Volume Switching .EOT
Figure 15
Example of a SCF status tape detail command