Slot and Port LED Behavior
LED
Pattern
Slot Fault
(for the slot in which
you are installing the
module)
1 FLASHING RAPIDLY if the module is not properly seated
2 ON for less than 1 second after the module has been
properly seated
3 OFF during normal switching operation
4 FLASHING SLOWLY if there is a self-test failure. Check the
switch event log through the console interface for more
information.
5 FLASHING SLOWLY if an incorrect transceiver (e.g., a
100Base-T transceiver) was installed in either of the 100VG
transceiver slots.
Note:
If the Fault LED for the module slot continues flashing
rapidly, the module may not be completely seated in the slot.
Ensure that the handles on the module are fully in the
“closed” position and the screws in the handles are
tightened.
If the module slot Fault LED continues flashing, unscrew the
screws, open the handles, remove the module, and re-install
it. If the Fault LED continues flashing, remove the module
and contact your HP-authorized LAN dealer or HP
networking support representative.
If a module is not installed properly, and the module slot
Fault LED continues rapid flashing, normal switch operation
halts until the module is removed or properly installed (the
other modules in the switch do continue to forward packets
normally).
Self-test
(for the Switch 2000)
1
ON for up to 40 seconds after the module has
been properly seated
2
OFF during normal switching operation
3
FLASHING simultaneously with slot Fault LED if the slot
has failed self-test. Check the event log.
5
Содержание AdvanceStack 100VG
Страница 1: ...HP AdvanceStack Switch 100VG Module Installation Guide ...
Страница 6: ......
Страница 8: ......
Страница 25: ......