Message
Type
Description
Action
44 REDUNDANCY
FAILED MISMATCH
HARDWARE
Error
Both array controllers must
contain the same hardware
for them to successfully
enter redundant mode. The
current array controllers
do not contain the same
hardware, possibly because
one has an attached Fibre
Channel daughter card and
the other does not.
If the MSA is currently
involved in host I/O, remove
the
standby
array controller,
add or replace the Fibre
Channel daughter card as
needed, wait 10 seconds,
and then reinsert it, ensuring
that it is fully seated in the
chassis.
If this does not resolve the
issue, wait until downtime
is available. Power off the
MSA, remove both array
controllers, add or remove
Fibre Channel daughter
cards as needed on both,
and reinsert them, ensuring
they are fully seated in the
chassis.
Should the issue persist,
contact HP support.
45 REDUNDANCY
FAILED MISMATCH
FIRMWARE
Error
Both array controllers must
be running the same version
of
fi
rmware for them to
successfully enter redundant
mode. A process called
fi
rmware cloning, which
attempts to make them both
the same
fi
rmware level,
has failed.
Manually update the
fi
rmware on the older array
controller. For instructions,
see the MSA
fi
rmware
updating guide.
46 REDUNDANCY
HALTED EXPAND
ACTIVE
Informational
If volume expansion is in
progress then redundancy
is not supported. Volume
expansion is initiated and
tracked using the Array
Con
fi
guration Utility (ACU).
After the volume expansion
is complete, redundancy is
automatically reestablished.
47 REDUNDANCY
FAILED CACHE SIZE
MISMATCH
Error
Both array controllers must
have the same size of cache
memory to successfully
enter redundant mode.
If the MSA is currently
involved in host I/O, remove
the
standby
array controller,
add or remove cache
memory as needed, wait 10
seconds, and then reinsert it,
ensuring that it is fully seated
in the chassis.
If this does not resolve the
issue, wait until downtime
is available. Power off the
MSA, remove both array
controllers, add or remove
cache memory as needed
on both, and reinsert them,
ensuring they are fully seated
in the chassis.
Should the issue persist,
contact HP support.
42
LCD panel and message descriptions
Содержание AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Страница 8: ...8 ...
Страница 12: ...12 About this guide ...
Страница 18: ...18 Specifications ...
Страница 60: ...60 LCD panel and message descriptions ...
Страница 96: ...96 Capacity expansion and extension ...
Страница 102: ...102 Hard drive failures and faulted LUNs ...
Страница 108: ...108 SCSI hard drive firmware ...