On or Off‘
Blinking
Off
The hard drive is being accessed in
one
of the following ways:
•
The hard drive is a replacement hard drive and is being
rebuilt.
•
If the online LEDs of all of the other hard drives in the array
are blinking, an expansion is occurring.
Do not remove the hard drive. Removing a hard drive at this
time can cause data loss.
Off
Off
On
The hard drive has failed and has been placed of
fl
ine. It is safe
to replace the hard drive.
Off, On, or
Blinking
On
Off
The hard drive is online and con
fi
gured as part of an array, If
necessary, and if all other hard drives in the same array are
online and working, it is safe to replace the hard drive.
one
of the following is happening:
•
If the Activity LED is Off, the drive is con
fi
gured and online,
but not currently active.
•
If the Activity LED is On or blinking, the drive is con
fi
gured
and online, and is currently active.
Off, On, or
Blinking
On or Off
Blinking
A predictive failure alert has been received for this drive. Replace
the hard drive as soon as possible.
maintenance and service guide
25