Table 16 4/64 SAN Switch nonport side LED patterns during normal
operation
LED name
LED color
Hardware status
Recommended action
No light
Power supply is not receiving
power or power is off.
Verify that the power supply is on
and seated and the power cord is
connected to a functioning power
source.
Steady green Power supply is operating
normally.
No action required.
Power Supply
Status
Steady
amber (for
more than 5
seconds)
Power supply fault for one of the
following reasons:
Power cable is disconnected.
Power supply is off. Power supply
has failed.
During POST, the LED displays
amber.
Try the following:
Check the power cable connection.
Verify that the power supply is
powered on.
Replace the power supply.
No light
Fan assembly is not receiving
power.
Verify that the fan assembly is
seated in the switch.
Verify that the switch is powered
on.
Steady green Fan assembly is operating
normally.
No action required.
Fan Status
Steady
amber (for
more than 5
seconds)
One or more of the fans in the fan
assembly failed or the fan FRU
was disabled by the user.
Verify that the fan FRU is enabled
(use
fanenable
command). If
the fan FRU is enabled, the FRU is
faulty and should be replaced.
84
Managing SAN Switches
Содержание AA-RWF3A-TE
Страница 1: ...HP StorageWorks SAN Switch installation guide Part number AA RWF3A TE Fifth edition May 2007 ...
Страница 7: ...Supported HBAs 145 Glossary 147 Index 157 SAN Switch installation guide 7 ...
Страница 10: ...10 ...
Страница 64: ...64 Installing and configuring SAN Switches ...
Страница 90: ...90 Managing SAN Switches ...
Страница 117: ...Japanese notice Korean notices SAN Switch installation guide 117 ...
Страница 146: ...146 SAN Switch technical specifications ...
Страница 156: ...156 Glossary ...