Installing Core Switch 2/64 FRUs
136
Core Switch 2/64 V4.1 Installation Guide
3. Enter the
hashow
command to determine which CP card is active (see
).
Figure 31: Sample output for the hashow command
Note:
Enter all remaining commands from the serial console for the active CP card,
unless otherwise indicated. For more information about commands, refer to the
HP
StorageWorks Fabric OS Version 3.1.x/4.1.x Reference Guide.
4. If the healthy CP card is performing as the active CP card, continue with
step 7
. If the faulty CP card is performing as the active CP card, fail over the
a.
Create a serial connection to the faulty CP card (repeat
step 1
, on
page 135).
b. Log into the serial console as Admin and enter 0 to log into logical Switch
0.
c.
Enter the
hafailover
command. The healthy CP card becomes the
active CP card.
d. Wait until the Status LED on the healthy CP card is no longer lit
(indicates failover is complete).
e.
Enter the
hashow
command from the serial console for the healthy CP
card to verify the failover.
SW0:admin> haShow
Local CP (Slot 5, CP0): Active
Remote CP (Slot 6, CP1): Standby, Healthy
HA enabled, Heartbeat Up
SWO:admin>
Содержание AA-RS2WC-TE
Страница 12: ...Contents 12 Core Switch 2 64 V4 1 Installation Guide ...
Страница 34: ...Overview 34 Core Switch 2 64 V4 1 Installation Guide ...
Страница 88: ...Installing and Configuring the Core Switch 2 64 88 Core Switch 2 64 V4 1 Installation Guide ...
Страница 168: ...Running Routine Operations 168 Core Switch 2 64 V4 1 Installation Guide ...
Страница 198: ...Technical Specifications 198 Core Switch 2 64 V4 1 Installation Guide ...
Страница 206: ...Regulatory Compliance Notices 206 Core Switch 2 64 V4 1 Installation Guide Taiwanese Notice BSMI EMC Statement Taiwan ...
Страница 207: ...Regulatory Compliance Notices 207 Core Switch 2 64 V4 1 Installation Guide RRL EMC Statement Korea ...
Страница 224: ...Setting Up and Configuring Modems 224 Core Switch 2 64 V4 1 Installation Guide ...