Installing Core Switch 2/64 FRUs
139
Core Switch 2/64 V4.1 Installation Guide
Replacing a Filler Panel or CP Card
Use these steps to remove a filler panel or CP card.
Caution:
Wear an ESD grounding strap when handling a CP card. The
chassis provides a grounding connection above the power connectors. Hold
the CP card by the edges of the metal pan (not by the ejectors).
1. If removing a filler panel, push the yellow button on each ejector in, open
both ejectors all the way, and slide the filler panel out of the chassis.
2. If removing a CP card, first determine which CP card is the active CP card as
follows:
a.
Log onto the switch from a terminal emulator application, (such as
HyperTerminal on Windows systems, or TERM in a Unix or Linux
environment).
b. Configure terminal emulator settings. Refer to the “Setting Network
Addresses via a Network Connection” section in chapter 2 for correct
values.
c.
Enter
haShow
at the prompt.
d. If the card you are replacing is the:
— Standby CP card, continue with step 2.
— Active CP card, type
haFailover
at the prompt. This command
causes the two CP cards to switch roles, (that is, the standby CP card
becomes the new active CP card).
Note:
The
haFailover
command causes the active CP card to failover to the
standby CP card. The standby CP card is now the active CP card.
3. Disconnect the following cables, if present:
a.
Modem cable from the modem serial port
b. Serial cable from the terminal serial port
c.
Ethernet cable from the Ethernet port
Содержание AA-RS2WC-TE
Страница 12: ...Contents 12 Core Switch 2 64 V4 1 Installation Guide ...
Страница 34: ...Overview 34 Core Switch 2 64 V4 1 Installation Guide ...
Страница 88: ...Installing and Configuring the Core Switch 2 64 88 Core Switch 2 64 V4 1 Installation Guide ...
Страница 168: ...Running Routine Operations 168 Core Switch 2 64 V4 1 Installation Guide ...
Страница 198: ...Technical Specifications 198 Core Switch 2 64 V4 1 Installation Guide ...
Страница 206: ...Regulatory Compliance Notices 206 Core Switch 2 64 V4 1 Installation Guide Taiwanese Notice BSMI EMC Statement Taiwan ...
Страница 207: ...Regulatory Compliance Notices 207 Core Switch 2 64 V4 1 Installation Guide RRL EMC Statement Korea ...
Страница 224: ...Setting Up and Configuring Modems 224 Core Switch 2 64 V4 1 Installation Guide ...