The cards on the A10500 Switch Series can be installed in horizontal or vertical slots, and the
replacement procedures are the same. The following takes a card installed in a horizontal slot as an
example.
To replace a card:
1.
Prepare an antistatic mat to place the removed card.
2.
Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well
grounded. For more information, see the chapter “Installing modules.”
3.
Use a Philips screwdriver to remove the captive screw on the card, as shown in callout 1 on
Figure
38
.
4.
Move the ejector levers outwards to separate the card from the backplane, as shown in callout 2
on
Figure 38
.
5.
Use one hand to slowly move the card outwards. Supporting the bottom of the card with the other
hand, pull the card out of the slot along slide rails, as shown in callout 3 on
Figure 38
.
6.
Put the removed card on the antistatic mat.
7.
Install a new card. For the installation procedures, see the chapter “Installing modules.”
Figure 38 Replace a card
2
2
3
1
(1) Loosen the captive screw
(2) Move the ejector levers outwards
(3) Take out the card
NOTE:
If no new card is to be installed, install a blank panel to ensure heat dissipation of the switch and prevent
dust from entering the switch.
Replacing a fan tray
When the fan tray fails, replace the fan tray to ensure normal operation of the switch.