To bring back the trace of the previous section, enter the command:
load trace trcfile <RETURN>
display trace <RETURN>
The trace information stored in "trcfile.TR " is restored, and you
can view the trace as you would any other trace.
The restored trace depth is the depth specified when the trace was
stored and cannot be increased. You may want to increase the
trace depth before storing traces.
When a trace is loaded, the trace command is not restored. A
"trace again" or "trace modify" command will use the last trace
command entered, not the command which resulted in the loaded
trace. Also, the trace status shown by the "display status" command
does not reflect the loaded trace.
1
Stopping the Trace
You can, and most likely will, specify traces whose trigger or
storage states are never found. When this happens, the "Trace
complete" message is never shown, and the trace continues to run
("Trace running"). When these situations occur, you can choose to
halt the trace measurement with the following command:
stop_trace <RETURN>
The "stop_trace" command is also useful to deactivate signals
which are driven when the trigger is found (refer to the
"Coordinated Measurements" chapter in the Softkey Interface
Reference manual).
Getting Started 2-29
Содержание 64700 series
Страница 2: ......
Страница 19: ...Tables Table 9 1 Summary of Commands 9 4 Table 9 2 Command Assignments 9 5 Contents 11 ...
Страница 20: ...1 Notes 12 Contents ...
Страница 24: ...1 Notes 1 4 Introduction ...
Страница 106: ...1 Notes 4 36 Performance Measurements ...
Страница 118: ...Figure 5 8 True Demultiplexing 5 12 Using the External Analyzer ...
Страница 128: ...1 Notes 6 6 Timing Introduction ...
Страница 134: ...1 Notes 7 6 Timing Getting Started ...
Страница 168: ...1 Notes 8 34 Timing Using the Analyzer ...
Страница 176: ...1 compare This command specifies a post processing compare definition Syntax 9 8 Timing Commands ...
Страница 182: ...1 copy This command copies specifications displays or measurement data to selected output Syntax 9 14 Timing Commands ...
Страница 191: ...define DATA xbits 8 width 8 RETURN Related Commands delete rename threshold Timing Commands 9 23 ...
Страница 200: ...Examples execute repetitively RETURN Related Commands halt halt_repetitive_execution 9 32 Timing Commands ...
Страница 201: ...1 find This command finds a trigger like event in trace memory Syntax Timing Commands 9 33 ...
Страница 219: ...1 mark This command marks specified conditions in trace memory Syntax Timing Commands 9 51 ...
Страница 236: ...1 process_for_data This command limits the trace list display to specified samples Syntax 9 68 Timing Commands ...
Страница 254: ...1 trigger This command specifies trigger conditions Syntax 9 86 Timing Commands ...
Страница 261: ...Examples display timing_diagram RETURN waveform_size medium RETURN Related Commands present Timing Commands 9 93 ...
Страница 262: ...1 Notes 9 94 Timing Commands ...
Страница 280: ...1 Notes B 16 Timing Diagrams and Outputs ...
Страница 292: ...1 Notes C 12 Timing Messages ...