Notice in the resulting trace (you may have to press < NEXT> )
that the enable and disable states have the "sq adv" string in the line
number column. This is because the windowing feature uses the
analyzer’s sequencer.
The windowing capabilities from within the Softkey Interface are
not as powerful or flexible as they are from within the Terminal
Interface. For example, in the Terminal Interface, you can set up a
windowing trace specification where the trigger does not have to be
in the window. If you do not find the windowing flexibility you
need from within Softkey Interface, refer to the Terminal Interface:
Analyzer User’s Guide.
1
Storing and
Loading Trace
Commands
You can save a trace command to a "trace specification" file and
reload it at a later time. To store the current trace command, enter:
store trace_spec tspecfile <RETURN>
The trace command is saved in a file named "tspecfile.TS" in the
current directory. The extension ".TS" is appended to trace
specification files if no extension is specified in the "store
trace_spec" command. Enter another trace command to overwrite
the existing trace command:
trace <RETURN>
To bring back the trace command saved in "tspecfile.TS" and
perform a trace measurement using it, enter the commands:
load trace_spec tspecfile <RETURN>
trace again <RETURN>
Trace commands that have just been loaded will always work, even
if symbols have been changed; however, once you modify the trace
command, it may no longer work.
Getting Started 2-27
Содержание 64700 series
Страница 2: ......
Страница 19: ...Tables Table 9 1 Summary of Commands 9 4 Table 9 2 Command Assignments 9 5 Contents 11 ...
Страница 20: ...1 Notes 12 Contents ...
Страница 24: ...1 Notes 1 4 Introduction ...
Страница 106: ...1 Notes 4 36 Performance Measurements ...
Страница 118: ...Figure 5 8 True Demultiplexing 5 12 Using the External Analyzer ...
Страница 128: ...1 Notes 6 6 Timing Introduction ...
Страница 134: ...1 Notes 7 6 Timing Getting Started ...
Страница 168: ...1 Notes 8 34 Timing Using the Analyzer ...
Страница 176: ...1 compare This command specifies a post processing compare definition Syntax 9 8 Timing Commands ...
Страница 182: ...1 copy This command copies specifications displays or measurement data to selected output Syntax 9 14 Timing Commands ...
Страница 191: ...define DATA xbits 8 width 8 RETURN Related Commands delete rename threshold Timing Commands 9 23 ...
Страница 200: ...Examples execute repetitively RETURN Related Commands halt halt_repetitive_execution 9 32 Timing Commands ...
Страница 201: ...1 find This command finds a trigger like event in trace memory Syntax Timing Commands 9 33 ...
Страница 219: ...1 mark This command marks specified conditions in trace memory Syntax Timing Commands 9 51 ...
Страница 236: ...1 process_for_data This command limits the trace list display to specified samples Syntax 9 68 Timing Commands ...
Страница 254: ...1 trigger This command specifies trigger conditions Syntax 9 86 Timing Commands ...
Страница 261: ...Examples display timing_diagram RETURN waveform_size medium RETURN Related Commands present Timing Commands 9 93 ...
Страница 262: ...1 Notes 9 94 Timing Commands ...
Страница 280: ...1 Notes B 16 Timing Diagrams and Outputs ...
Страница 292: ...1 Notes C 12 Timing Messages ...