![HP 64700 series Скачать руководство пользователя страница 102](http://html.mh-extra.com/html/hp/64700-series/64700-series_user-manual_161481102.webp)
Note
If you are making duration measurements on a function that is
recursive, or one that has multiple entry and/or exit points, you
may wind up with invalid information.
Example Duration Measurement
The following examples assume that the SPMT demo program has
been loaded into the emulator and is executing.
display trace depth 512 <RETURN>
trace after math_library start or
math_library end
only math_library start or
math_library end <RETURN>
The "trace" specification sets up the analyzer to capture only the
states that contain the start address of the "math_library" function
or the end address of the "math_library" function. Since the trigger
state is also stored, the analyzer is set up to trigger on the entry or
exit address of the "math_library" function. With these states in
memory, the analyzer will derive two measurements: time from
start to end of math_library, and time from end to start of
math_library.
Enter the following command to initialize the duration
measurement:
performance_measurement_initialize
time_ranges
duration <RETURN>
The "time_ranges" file contains:
1 us 20 us
21 us 40 us
41 us 60 us
61 us 80 us
81 us 100 us
101 us 120 us
121 us 140 us
141 us 160 us
161 us 180 us
181 us 200 us
201 us 5 ms
You can fork a shell to HP-U X (by entering "! < R ETUR N> " on
the Softkey Interface command line) and create the "time_ranges"
4-32 Performance Measurements
Содержание 64700 series
Страница 2: ......
Страница 19: ...Tables Table 9 1 Summary of Commands 9 4 Table 9 2 Command Assignments 9 5 Contents 11 ...
Страница 20: ...1 Notes 12 Contents ...
Страница 24: ...1 Notes 1 4 Introduction ...
Страница 106: ...1 Notes 4 36 Performance Measurements ...
Страница 118: ...Figure 5 8 True Demultiplexing 5 12 Using the External Analyzer ...
Страница 128: ...1 Notes 6 6 Timing Introduction ...
Страница 134: ...1 Notes 7 6 Timing Getting Started ...
Страница 168: ...1 Notes 8 34 Timing Using the Analyzer ...
Страница 176: ...1 compare This command specifies a post processing compare definition Syntax 9 8 Timing Commands ...
Страница 182: ...1 copy This command copies specifications displays or measurement data to selected output Syntax 9 14 Timing Commands ...
Страница 191: ...define DATA xbits 8 width 8 RETURN Related Commands delete rename threshold Timing Commands 9 23 ...
Страница 200: ...Examples execute repetitively RETURN Related Commands halt halt_repetitive_execution 9 32 Timing Commands ...
Страница 201: ...1 find This command finds a trigger like event in trace memory Syntax Timing Commands 9 33 ...
Страница 219: ...1 mark This command marks specified conditions in trace memory Syntax Timing Commands 9 51 ...
Страница 236: ...1 process_for_data This command limits the trace list display to specified samples Syntax 9 68 Timing Commands ...
Страница 254: ...1 trigger This command specifies trigger conditions Syntax 9 86 Timing Commands ...
Страница 261: ...Examples display timing_diagram RETURN waveform_size medium RETURN Related Commands present Timing Commands 9 93 ...
Страница 262: ...1 Notes 9 94 Timing Commands ...
Страница 280: ...1 Notes B 16 Timing Diagrams and Outputs ...
Страница 292: ...1 Notes C 12 Timing Messages ...