The cursor can also be positioned by entering the relative sample
number on the command line. The command
100 <RETURN>
moves the cursor to sample number one hundred, while the
command
-50 <RETURN>
positions the cursor at sample number minus fifty. In all cases, if
the corresponding sample is not currently on the display, it will be
centered in the display.
R efer "Locating Events in Trace Memory" later in this section for
more information on positioning the cursor.
Showing Levels at
the Cursor
The level for each of the signals is depicted in the waveform. You
can also choose to display the signal level, high ("H"), low ("L"), or
glitch ("G"), at the current cursor position by enabling that feature.
The command
indicate levels_at_cursor on <RETURN>
enables the display of signals levels at the cursor. The levels are
indicated to the right of the labels.
Magnifying the
Diagram
The default magnification of the trace memory data is x4. With this
magnification, a standard mode sample fills the waveform. A
higher magnification indicates that more detail is displayed (less
trace memory is depicted in the waveform) and a lower
magnification indicates that less detail is displayed.
The command
magnify x100 <RETURN>
changes the "magnification" on the trace to 100 times.
Changing the
Waveform Size
The relative vertical size of the waveform can be changed to make
visualization easier. You can set the waveform to small, medium,
or large. Small is the default waveform size.
8-16 Timing: Using the Analyzer
Содержание 64700 series
Страница 2: ......
Страница 19: ...Tables Table 9 1 Summary of Commands 9 4 Table 9 2 Command Assignments 9 5 Contents 11 ...
Страница 20: ...1 Notes 12 Contents ...
Страница 24: ...1 Notes 1 4 Introduction ...
Страница 106: ...1 Notes 4 36 Performance Measurements ...
Страница 118: ...Figure 5 8 True Demultiplexing 5 12 Using the External Analyzer ...
Страница 128: ...1 Notes 6 6 Timing Introduction ...
Страница 134: ...1 Notes 7 6 Timing Getting Started ...
Страница 168: ...1 Notes 8 34 Timing Using the Analyzer ...
Страница 176: ...1 compare This command specifies a post processing compare definition Syntax 9 8 Timing Commands ...
Страница 182: ...1 copy This command copies specifications displays or measurement data to selected output Syntax 9 14 Timing Commands ...
Страница 191: ...define DATA xbits 8 width 8 RETURN Related Commands delete rename threshold Timing Commands 9 23 ...
Страница 200: ...Examples execute repetitively RETURN Related Commands halt halt_repetitive_execution 9 32 Timing Commands ...
Страница 201: ...1 find This command finds a trigger like event in trace memory Syntax Timing Commands 9 33 ...
Страница 219: ...1 mark This command marks specified conditions in trace memory Syntax Timing Commands 9 51 ...
Страница 236: ...1 process_for_data This command limits the trace list display to specified samples Syntax 9 68 Timing Commands ...
Страница 254: ...1 trigger This command specifies trigger conditions Syntax 9 86 Timing Commands ...
Страница 261: ...Examples display timing_diagram RETURN waveform_size medium RETURN Related Commands present Timing Commands 9 93 ...
Страница 262: ...1 Notes 9 94 Timing Commands ...
Страница 280: ...1 Notes B 16 Timing Diagrams and Outputs ...
Страница 292: ...1 Notes C 12 Timing Messages ...