![HP 64700 series Скачать руководство пользователя страница 161](http://html.mh-extra.com/html/hp/64700-series/64700-series_user-manual_161481161.webp)
marks from mark_x to mark_o is greater than (or less than) a
specified number of marks.
Logging Statistics
You can log the detail from each sample to a file for subsequent
review. The "statistics"‘ command in the post processing
specification allows you to specify a file name to write the
information. For logging to occur, one of the statistical analysis
calculation options must have been previously chosen.
The commands
display timing_diagram <RETURN>
indicate time_interval_x_o
mean_and_standard_deviation <RETURN>
post statistics log_to_file STATISTICS
<RETURN>
post halt_repetitive_execution
when_runs_equal 8 <RETURN>
execute repetitively <RETURN>
start a eight run statistical trace. After execution halts, enter the
command
post statistics log_to_file none <RETURN>
to disable statistics logging. The generated output logs will look
like:
64700 Timing Analyzer Mon Jun 19 14:47:05 1989
Time x_o 1.66 usec x=-54 o=+112 Runs=1 Mon Jun 19 14:47:20 1989
Max=1.66 usec Min=1.66 usec Mean=1.66 usec Stdv=0.0 nsec
Time x_o 5.77 usec x=-54 o=+523 Runs=2 Mon Jun 19 14:47:30 1989
Max=5.77 usec Min=1.66 usec Mean=3.71 usec Stdv=2.91 usec
Time x_o 7.82 usec x=-54 o=+728 Runs=3 Mon Jun 19 14:47:40 1989
Max=7.82 usec Min=1.66 usec Mean=5.08 usec Stdv=3.14 usec
Time x_o 3.47 usec x=-54 o=+293 Runs=4 Mon Jun 19 14:47:50 1989
Max=7.82 usec Min=1.66 usec Mean=4.68 usec Stdv=2.69 usec
Time x_o 1.62 usec x=-54 o=+108 Runs=5 Mon Jun 19 14:48:00 1989
Max=7.82 usec Min=1.62 usec Mean=4.07 usec Stdv=2.70 usec
Time x_o 7.10 usec x=-54 o=+656 Runs=6 Mon Jun 19 14:48:11 1989
Max=7.82 usec Min=1.62 usec Mean=4.57 usec Stdv=2.71 usec
Time x_o 2.32 usec x=-54 o=+178 Runs=7 Mon Jun 19 14:48:21 1989
Max=7.82 usec Min=1.62 usec Mean=4.25 usec Stdv=2.62 usec
Time x_o 2.32 usec x=-54 o=+178 Runs=8 Mon Jun 19 14:48:34 1989
Max=7.82 usec Min=1.62 usec Mean=4.01 usec Stdv=2.52 usec
Timing: Using the Analyzer 8-27
Содержание 64700 series
Страница 2: ......
Страница 19: ...Tables Table 9 1 Summary of Commands 9 4 Table 9 2 Command Assignments 9 5 Contents 11 ...
Страница 20: ...1 Notes 12 Contents ...
Страница 24: ...1 Notes 1 4 Introduction ...
Страница 106: ...1 Notes 4 36 Performance Measurements ...
Страница 118: ...Figure 5 8 True Demultiplexing 5 12 Using the External Analyzer ...
Страница 128: ...1 Notes 6 6 Timing Introduction ...
Страница 134: ...1 Notes 7 6 Timing Getting Started ...
Страница 168: ...1 Notes 8 34 Timing Using the Analyzer ...
Страница 176: ...1 compare This command specifies a post processing compare definition Syntax 9 8 Timing Commands ...
Страница 182: ...1 copy This command copies specifications displays or measurement data to selected output Syntax 9 14 Timing Commands ...
Страница 191: ...define DATA xbits 8 width 8 RETURN Related Commands delete rename threshold Timing Commands 9 23 ...
Страница 200: ...Examples execute repetitively RETURN Related Commands halt halt_repetitive_execution 9 32 Timing Commands ...
Страница 201: ...1 find This command finds a trigger like event in trace memory Syntax Timing Commands 9 33 ...
Страница 219: ...1 mark This command marks specified conditions in trace memory Syntax Timing Commands 9 51 ...
Страница 236: ...1 process_for_data This command limits the trace list display to specified samples Syntax 9 68 Timing Commands ...
Страница 254: ...1 trigger This command specifies trigger conditions Syntax 9 86 Timing Commands ...
Страница 261: ...Examples display timing_diagram RETURN waveform_size medium RETURN Related Commands present Timing Commands 9 93 ...
Страница 262: ...1 Notes 9 94 Timing Commands ...
Страница 280: ...1 Notes B 16 Timing Diagrams and Outputs ...
Страница 292: ...1 Notes C 12 Timing Messages ...