Troubleshooting 3-17
HP-UX Procedure:
1.
Reset the system.
2.
Stop the autoboot process if it is enabled.
3.
From PDC service menu, enter the
PIM
command. Record or print the PIM report, specifically
timestamps, chassis codes, responder/requestor addresses, I/O module error log, and memory error
log.
4.
Refer to Table 3-12 for description and action for each HPMC chassis code. Table 3-13 identifies the
slot numbers on the Processor/Memory bus.
MPE/iX Procedure:
1.
Perform a TOC.
2.
From the PDC service menu, enter the
PIM
command. Record or print the PIM report, specifically
timestamps, chassis codes, responder/requestor addresses, I/O module error log, and memory error
log.
3.
Perform a memory dump (refer to Performing a Memory Dump section).
4.
Refer to Table 3-12 for description and action for each HPMC chassis code.
For Major Category 5 (Bus Transactions) Chassis Codes, the Master ID (MID) will identify the CPU or IOA
as follows:
Description
SPA
K2x0/K4x0
K370/K380
K570/K580
MID
CPU 0
FFFA0000
0
0
0
CPU 1
FFFA2000
1
1
1
CPU 2
FFFA4000
2
2
2
CPU 3
FFFA6000
3
3
3
CPU 4
FFFAC000
—
6
6
CPU 5
FFFAE000
—
7
7
IOA 0 (system board)
FFF88000
4
4
4
IOA 1 (system board)
FFF8A000
5
5
5
IOA 0 (HSC expansion I/O)
FFF8C000
—
—
6
IOA 1 (HSC expansion I/O)
FFF8E000
—
—
7
MMC
FFFB1000
7
—
—
Содержание 3000/9x9KS Series
Страница 14: ...xiv Contents E Sources of Information on the Web ...
Страница 28: ...2 8 Install and Configuration Figure 2 4 HP PB I O Slot Location Diagram Kx70 Kx80 ...
Страница 44: ...2 24 Install and Configuration ...
Страница 68: ...3 24 Troubleshooting HP 3000 Core I O Figure 3 4 HP 3000 Core I O ...
Страница 120: ...5 6 Diagnostics ...
Страница 128: ...6 8 Replaceable Parts Figure 6 4 Peripheral Bay Expanded View ...
Страница 136: ...6 16 Replaceable Parts ...
Страница 150: ...7 14 Removal and Replacement Figure 7 11 Peripheral Bay Rear View ...
Страница 173: ...Removal and Replacement 7 37 Figure 7 29 Kx70 System Board Figure 7 30 Frequency Switch Settings ...
Страница 180: ...7 44 Removal and Replacement Figure 7 35 Cabinet Exploded View Rear ...
Страница 209: ...SCSI and I O 8 21 Figure 8 3 A3629A ST19171WD J2 and J6 Jumper Settings ...
Страница 217: ...SCSI and I O 8 29 Figure 8 7 A3353A source 2 J3 Jumper Positions ...
Страница 218: ...8 30 SCSI and I O Figure 8 8 A3353A source 2 Option Connector Jumper Positions ...
Страница 258: ...8 70 SCSI and I O Exchange part Number The exchange part number is C2478SZ C1504 69201 Diagnostics SCSIDDS SYSMAP IOMAP ...
Страница 280: ...8 92 SCSI and I O Diagnostics CSTM SCSIDDS SYSMAP IOMAP ...
Страница 298: ...8 110 SCSI and I O Diagnostics SCSICD IOMAP SYSMAP ...
Страница 302: ...8 114 SCSI and I O ...
Страница 308: ...Support Information B 2 HP 9x9KS Block Diagram Figure B 1 HP 3000 9x9KS Block Diagram ...
Страница 309: ...B 3 Support Information HP K100 Block Diagram Figure B 2 HP 9000 K100 Block Diagram ...
Страница 310: ...Support Information B 4 HP K2x0 K4x0 Block Diagram Figure B 3 HP 9000 K2x0 K4x0 Block Diagram ...
Страница 311: ...B 5 Support Information Kx70 Kx80 Block Diagram Figure B 4 HP9000 Kx70 Block Diagram ...
Страница 342: ...Memory Configuration Guidelines C 16 ...
Страница 350: ...D 8 New System Features ...