D-2 New System Features
Firmware Differences
Expanded ChipRevision Information
In the PDC, the ChipRevision command in the Information Menu has been modified to provide additional
information. Following is an example of the new CR command:
Main Menu: Enter command or menu > in cr
Module Revision
------ --------
System Board 1
PA 8200 CPU Module 5.1
PA 8200 CPU Module 5.1
PA 8200 CPU Module 5.1
PA 8200 CPU Module 5.1
PA 8200 CPU Module 5.1
PA 8200 CPU Module 5.1
PDC Firmware 502
Tower 9
Memory Carrier 0 Regular
Memory Carrier 1 Not present
I/O Bus Adapter 0 15
Shrike Board 1
Zalon 2
I/O Bus Adapter 1 15
Core I/O Board 1
Zalon 2
GeckoBoa Not available
NIO module 0
Lasi 0
GeckoBoa Not available
HSC 1 (40MHz)
HSC 2 (32MHz)
Main Menu: Enter command or menu >
Configuration Issues
Beginning with this edition of the service manual, special configuration issues will be identified in this
section:
Memory for HP9000/Kx70/Kx80 Servers:
Kx70/Kx80 systems with four to six CPUs that use the minimum 256MB memory size REQUIRE that the
memory consist of at least four SIMMs (two modules).
Содержание 3000/9x9KS Series
Страница 14: ...xiv Contents E Sources of Information on the Web ...
Страница 28: ...2 8 Install and Configuration Figure 2 4 HP PB I O Slot Location Diagram Kx70 Kx80 ...
Страница 44: ...2 24 Install and Configuration ...
Страница 68: ...3 24 Troubleshooting HP 3000 Core I O Figure 3 4 HP 3000 Core I O ...
Страница 120: ...5 6 Diagnostics ...
Страница 128: ...6 8 Replaceable Parts Figure 6 4 Peripheral Bay Expanded View ...
Страница 136: ...6 16 Replaceable Parts ...
Страница 150: ...7 14 Removal and Replacement Figure 7 11 Peripheral Bay Rear View ...
Страница 173: ...Removal and Replacement 7 37 Figure 7 29 Kx70 System Board Figure 7 30 Frequency Switch Settings ...
Страница 180: ...7 44 Removal and Replacement Figure 7 35 Cabinet Exploded View Rear ...
Страница 209: ...SCSI and I O 8 21 Figure 8 3 A3629A ST19171WD J2 and J6 Jumper Settings ...
Страница 217: ...SCSI and I O 8 29 Figure 8 7 A3353A source 2 J3 Jumper Positions ...
Страница 218: ...8 30 SCSI and I O Figure 8 8 A3353A source 2 Option Connector Jumper Positions ...
Страница 258: ...8 70 SCSI and I O Exchange part Number The exchange part number is C2478SZ C1504 69201 Diagnostics SCSIDDS SYSMAP IOMAP ...
Страница 280: ...8 92 SCSI and I O Diagnostics CSTM SCSIDDS SYSMAP IOMAP ...
Страница 298: ...8 110 SCSI and I O Diagnostics SCSICD IOMAP SYSMAP ...
Страница 302: ...8 114 SCSI and I O ...
Страница 308: ...Support Information B 2 HP 9x9KS Block Diagram Figure B 1 HP 3000 9x9KS Block Diagram ...
Страница 309: ...B 3 Support Information HP K100 Block Diagram Figure B 2 HP 9000 K100 Block Diagram ...
Страница 310: ...Support Information B 4 HP K2x0 K4x0 Block Diagram Figure B 3 HP 9000 K2x0 K4x0 Block Diagram ...
Страница 311: ...B 5 Support Information Kx70 Kx80 Block Diagram Figure B 4 HP9000 Kx70 Block Diagram ...
Страница 342: ...Memory Configuration Guidelines C 16 ...
Страница 350: ...D 8 New System Features ...