Display Codes 4-25
Selftest Console Display Messages
The Boot Console Handler (BCH) messages in this section pertain to memory or processor related warning
messages. These messages would be displayed during the particular components selftest routine. These
warnings can also be displayed on the console by issuing the warn command (Kx50, Kx60, and Kx70
systems)
Memory Warning Messages
There are seven possible memory warning messages that may be displayed, they are as follows:
Not enough error-free contiguous memory (GoodMem). Refer to the ME command in the INFORMATION
menu, and the PDT command in the SERVICE menu for error information.
Memory page deallocation has been disabled because the Page Deallocation Table (PDT) is full. If the
Boot command is disabled, a memory error was detected after the table was full. Refer to the PDT
command in the SERVICE menu for error information.
Memory has been initialized, but not tested as a result of FASTBOOT being enabled. To test memory, use
the FASTBOOT command in the CONFIGURATION menu and reboot the system.
Memory configuration is not optimized for performance. Refer to Appendix C of this manual for memory
configuration guide lines.
An empty memory slot has been detected which should contain a SIMM. The Boot command has been
disabled to prevent thermal damage. Refer to the memory configuration label for proper sequence.
Memory has been reconfigured due to a physical change or because the Page Deallocation Table (PDT)
was cleared. This is for information only. No action is required.
Memory banks deallocated due to a SIMM size mismatch or a SIMM failure. Refer to the ME command in
the INFORMATION menu for error information.
Processor Warning Messages
There are two possible processor warning messages that may be displayed, they are as follows:
A processor has failed selftest and has been deconfigured. Refer to the PR command in the
INFORMATION menu for a list of deconfigured processors.
Processors are not installed in numerical order (0 to 5
).
Boot process has been halted. Refer to PR command in the INFORMATION menu for processor
configuration information.
NOTE
Some memory configurations which are valid may erroneously cause the following message to be
displayed. Verify memory configuration, and if valid disregard the message. If not valid, refer to
memory configuration rules and correct the problem.
Содержание 3000/9x9KS Series
Страница 14: ...xiv Contents E Sources of Information on the Web ...
Страница 28: ...2 8 Install and Configuration Figure 2 4 HP PB I O Slot Location Diagram Kx70 Kx80 ...
Страница 44: ...2 24 Install and Configuration ...
Страница 68: ...3 24 Troubleshooting HP 3000 Core I O Figure 3 4 HP 3000 Core I O ...
Страница 120: ...5 6 Diagnostics ...
Страница 128: ...6 8 Replaceable Parts Figure 6 4 Peripheral Bay Expanded View ...
Страница 136: ...6 16 Replaceable Parts ...
Страница 150: ...7 14 Removal and Replacement Figure 7 11 Peripheral Bay Rear View ...
Страница 173: ...Removal and Replacement 7 37 Figure 7 29 Kx70 System Board Figure 7 30 Frequency Switch Settings ...
Страница 180: ...7 44 Removal and Replacement Figure 7 35 Cabinet Exploded View Rear ...
Страница 209: ...SCSI and I O 8 21 Figure 8 3 A3629A ST19171WD J2 and J6 Jumper Settings ...
Страница 217: ...SCSI and I O 8 29 Figure 8 7 A3353A source 2 J3 Jumper Positions ...
Страница 218: ...8 30 SCSI and I O Figure 8 8 A3353A source 2 Option Connector Jumper Positions ...
Страница 258: ...8 70 SCSI and I O Exchange part Number The exchange part number is C2478SZ C1504 69201 Diagnostics SCSIDDS SYSMAP IOMAP ...
Страница 280: ...8 92 SCSI and I O Diagnostics CSTM SCSIDDS SYSMAP IOMAP ...
Страница 298: ...8 110 SCSI and I O Diagnostics SCSICD IOMAP SYSMAP ...
Страница 302: ...8 114 SCSI and I O ...
Страница 308: ...Support Information B 2 HP 9x9KS Block Diagram Figure B 1 HP 3000 9x9KS Block Diagram ...
Страница 309: ...B 3 Support Information HP K100 Block Diagram Figure B 2 HP 9000 K100 Block Diagram ...
Страница 310: ...Support Information B 4 HP K2x0 K4x0 Block Diagram Figure B 3 HP 9000 K2x0 K4x0 Block Diagram ...
Страница 311: ...B 5 Support Information Kx70 Kx80 Block Diagram Figure B 4 HP9000 Kx70 Block Diagram ...
Страница 342: ...Memory Configuration Guidelines C 16 ...
Страница 350: ...D 8 New System Features ...